A Computer Navigation System Analysis of the Accuracy of the Extramedullary (Tibial) Alignment Technique in Total Knee Arthroplasty (TKA)
Journal Title: Malaysian Orthopaedic Journal - Year 2010, Vol 4, Issue 2
Abstract
In total knee arthroplasty, mechanical alignment guides have improved the accuracy of implant alignment, but errors are not uncommon. In the present study, an image-free computer-assisted navigation system was used to analyse the accuracy of an extramedullary (tibial) alignment system, which is based on predetermined, fixed anatomical landmarks. Comparisons were made between two surgeons, with different levels of competency in order to determine if experience affected the accuracy of extramedullary tibial jig placement, in either the coronal and sagittal planes or both planes. The results showed that the accuracy of the extramedullary tibial alignment system, in the coronal plane (in up to 80-87% of cases) was much better than for posterior slope, and sagittal plane. Surgeon experience was not a significant factor
Authors and Affiliations
EK Chee, TW Ewe
Outcome of Surgery for Unstable Intertrochanteric Fractures in Octogenarians
This study aims to determine pre-morbid parameters as possible predictors of outcome of hip fracture in octogenarians with unstable intertrochanteric fracture treated operatively. Presence of co-morbidities, pre-injury l...
Femoral Shaft Cortical Pathology associated with longterm Alendronate Therapy: A New Classification
There are reported cases of cortical reaction over the tension side of the normal femoral shafts in patients on long term treatment with alendronate, leading to subsequent femoral shaft fractures. We performed a retrospe...
Resection Angulation Osteotomy in Treatment of Postseptic Ankylosis of the Hip
This study evaluated the results of the resection angulation osteotomy in post-septic ankylosis of hip. We performed the procedure in 19 patients, with average age of 26 years (range, 21-32 years) and followed patients p...
Fracture and Posterior Dislocation of Meniscal Bearing Insert in Mobile Bearing Unicompartmental Knee Arthroplasty: A Case Report
Dislocation of meniscal bearing insert is a rare but wellrecognised complication in meniscal bearing unicompartmental knee arthroplasty (UKA). On the other hand, fracture of meniscal bearing insert of phase III Oxford UK...
“‘Doc’ do I need an anterior cruciate ligament reconstruction? What happens if I do not reconstruct the cruciate ligament?”
We are all aware that there has been a dramatic increase in the number of anterior cruciate ligament (ACL) reconstructions that are carried out here in Malaysia as well as around the world. The numbers of ACL injuries ha...