A Prospective controlled comparative study of haemodynamic responses, intubating conditions to laryngoscopy and tracheal intubation by using Macintosh vs. Mc Coy blade laryngoscope
Journal Title: MRIMS Journal of Health Sciences - Year 2018, Vol 6, Issue 1
Abstract
Abstract: Background: The invention of McCoy blade in the early 1990s is a modification of the Macintosh blade with a hinged tip. The McCoy blade reduces the amount of force applied during laryngoscopy and endotracheal intubation, thus the increased reflex haemodynamic changes in response to tracheal intubation becomes less significant. Objective: To determine the advantages of McCoy blade laryngoscope in obtunding the pressor response, better glottic visualization and ease of intubation during laryngoscopy and endotracheal intubation as compared to Macintosh blade laryngoscope. Methods: The present study was done on 60 adult patients of ASA I and II, between the age group of 20 to 50 years. We observed the haemodynamic changes, glottic view and ease of intubation by using either Macintosh or McCoy blade laryngoscope during general anesthesia at laryngoscopy and endotracheal intubation. The changes in HR, SBP, DBP, and MAP were recorded before induction, at laryngoscopy and intubation and at 1 min, 3 min and 5 min after tracheal intubation. Glottic view obtained on laryngoscope was compared as per Cormack and Lehene grading. Tracheal intubation grading was also compared between the groups. Complications during the procedure like arrhythmias, injury, and bleeding were noted. Results: In our study, a significant haemodynamic changes were observed in both the groups following laryngoscopy and endotracheal intubation. The rise in HR, SBP, DBP and MAP were more significant with Macintosh blade laryngoscope, where as better visualization of the glottis, ease of intubation and less haemodynamic changes were noted with McCoy blade laryngoscope. Conclusion: McCoy blade laryngoscope produces significantly less marked haemodynamic changes, better glottic view and ease of intubation as compared to Macintosh blade laryngoscope during laryngoscopy and tracheal intubation. Key words: Macintosh blade, McCoy blade, endotracheal intubation, Haemodynamic response, glottic view
Authors and Affiliations
Sarada Devi V, Lakshmi Narasimham M, Manjula VR, Saroj P, Surender P
Nursing Students’ Perceptions on Objective Structured Clinical Examination (OSCE)
Background: Objective Structured Clinical Examination (OSCE) has been widely used in the assessment of students’ clinical performance. One of the strategies to improve the effectiveness is through assessing feedback from...
Prevalence of ABO & Rh blood groups in patients visiting Malla Reddy Health City, Suraram, Hyderabad
Background: Blood groups of different people have different antigenic and immune properties, so that, antibodies in the plasma of one blood react with antigens on the surface of the red cells of another blood type. If pr...
Clinical behaviour of ocular surface squamous neoplasia (OSSN) in HIV positive patients
Background: A lot of Ocular Surface Squamous Neoplasia(OSSN) may go unnoticed as they are asymptomatic and usually slow-growing. The prevalence of OSSN is more in tropical region and varies from 12 cases /million/ year i...
Supra condylar humerus fractures in children with close reduction and K wire fixation
Background: Supracondylar fractures are the most frequent elbow injuries in children, reported to occur in 55% to 75% of patients with elbow fractures. Objective: This study has been undertaken to observe the results of...
A study on stress levels among exam going post graduate medical students of a medical college in Telangana- A cross sectional study
Abstract: Background: Medicine is considered to be a stressful profession particularly during post graduate years. Stress is also linked to various diseases such as Hypertension and Diabetes etc. Hence, understanding st...