A Review Paper on Earth Tube Heat Exchanger
Journal Title: International Journal for Research in Applied Science and Engineering Technology (IJRASET) - Year 2015, Vol 3, Issue 11
Abstract
The aim of this work is to investigate by modeling the possibility of reducing the operational energy of a typical house without negatively affecting its embodied energy. This is done through consideration of different building materials coupled with the use of an earth to air heat exchanger (EAHE) for fresh air supply and cooling.It is found that the use of an optimal wall configuration in each zone coupled with the EAHE results in 76.7% energy savings compared with the reference case with conventional cooling.A single pass earth-tube heat exchanger (ETHE) was installed to study its performance in cooling and heating mode. ETHE is made of 50 m long MS pipe of 10 cm nominal diameter and 3 mm wall thickness. ETHE is buried 3 m deep below surface. Ambient air is pumped through it by a 400 w blower.Air velocity in the pipe is 11 m/s. Air temperature is measured at the inlet of the pipe, in the middle (25 m), and at the outlet (50 m), by thermistors placed inside the pipe. Cooling tests were carried out three consecutive days in each month.
Authors and Affiliations
Harish kant dhruw, Gopal Sahu, Prakash Kumar Sen, Ritesh Sharma
Fault Tolerant Parallel Filters Based on Error Correction Code
Digital filters are widely used in signal processing and communication systems. In some cases, the reliability of those systems is critical, and fault tolerant filter implementations are needed. Next many techniques tha...
A Novel Attraction Segregation based Image Compression Technique
Digital pictures need sizable amounts of bits to represent them and in their canonical illustration, usually contain important quantity of redundancy. Compression techniques scale back the amounts of bits needed to repr...
Analysis and Implementation of PMBLDC Motor Drive with CUK Converter
This method is used to improve the efficiency of motor drive by power factor correction. It plays an important role in energy saving during energy conversion. A cuk dc -dc converter topology reduced the power quality pr...
Short Term Load Forecasting Using Moving Averages
Electricity is an essential part of our life and without this nothing is possible an accurate and efficient Short term load forecasting plays a vital role for economic operational planning of both regulated power system...
Secure and Efficient Data Retrieval Using Attribute-Based Encryption in Distributed System
Attribute-based encryption (ABE) is a public-key based one-to-many encryption that allows users to encrypt and decrypt data based on user attributes. A promising application of ABE is flexible access control of encrypte...