A study of the advantages of the new device for percutaneous entry point in greater trochanter for any intra medullary fixation of the femur compared to the conventional methods

Journal Title: Medpulse International Journal of Orthopedics - Year 2019, Vol 10, Issue 2

Abstract

Background:In the past the most common surgery around the hip was DHS and Barrel plate for any trochanteric fractures. Of late the commonest surgeries done on the Femur are Proximal Femoral Nail (PFN) or the Interlocking Nailing for the fractures of the Femur or supracondylar nailing of the Femur. Aim:To study the advantages of the new device for percutaneous entry point in Greater Trochanter for any intra medullary fixation of the Femur compared to the conventional methods.Objectives: To access advantages of this new device over the conventional device used for the intramedullary femur entry point. The following intraoperative characteristics were compared by usage of new device and conventional device.1)C-Arm exposure time, 2)Technical difficulties during surgery along with complications, 3)Duration of surgery, 4)Blood loss, Materials and Methods:A total of sixty four cases are being treated from November 2017 to October 2018 at Bhaskar Medical College and Bhaskar General Hospital Yenkapally,thirty two cases each by this method of percutaneous entry point in the Trochanter using this new device and conventional device respectively for the Trochanteric fractures and for the fractures of shaft of the Femur.The device is designed by the author and his team indigenously in the work shop of the Mechanical engineering of Joginpally Institute of Engineering and Technology.All the patients gave the informed consent for inclusion into study and the study was authorized by the local ethical committee.Results:We have done this study in 64 patients, 32 patients each by new device and conventional device respectively. With the use of new device, there was ease getting into the exact point of entry in the Trochanter, the comfort of getting both AP and Lateral views of the C- arm pictures with avoidances of unnecessary exposure to radiation and minimal blood loss compared to the use of conventional device.Conclusion:The study has found that the new device is very effective and advantageous compared to the conventional device for percutaneous entry point in Greater Trochanter for any intra medullary fixation of the Femur

Authors and Affiliations

VS Ravindranath, BSreekanth Rao

Keywords

Related Articles

Association between femoral stem positioning and functional outcome in total hip arthroplasty

Background: The development of uncemented stems with hydroxyapatite (HA) coating may decrease the incidence of loosening, distal migration and may enhance integration and prosthetic stability. Aim: To evaluate the functi...

Idiopathic clubfoot management by Ponsetti technique hyperkyphosis

Background: Clubfoot is a birth defect where one or both feet are rotated inwards and downwards.The affected foot, calf and leg may be smaller than the other.In about half of those affected, both feet are involved Aims a...

Arthroscopic anterior cruciate ligament reconstruction: comparison between hamstring graft versus patellar bone tendon bone graft

Background: Anterior cruciate ligament (ACL) tear is the most common serious ligamentous injury to the knee joint. The ACL is the primary stabilizer against anterior translation of the tibia on the femur and is important...

Humeral shaft fracture: A hospital based study

Background: Fractures of the shaft of the humerus account for 1% to 3% of all fractures in adults. The incidence of humeral shaft fracture is 14.5 per 100,000 per year and which is gradually increasing from the fifth dec...

A comparative, prospective study of proximal femoral nail and dynamic hip screw in the treatment of stable intertrochanteric fractures in adult Indian patients

Background: Conservative treatment for intertrochanteric fractures (ITF) have shown higher mortality and have largely been abandoned. Rigid internal fixation and early mobilization is the current standard treatment. Meth...

Download PDF file
  • EP ID EP617241
  • DOI 10.26611/10201028
  • Views 75
  • Downloads 0

How To Cite

VS Ravindranath, BSreekanth Rao (2019). A study of the advantages of the new device for percutaneous entry point in greater trochanter for any intra medullary fixation of the femur compared to the conventional methods. Medpulse International Journal of Orthopedics, 10(2), 40-44. https://www.europub.co.uk/articles/-A-617241