AMBIENT WELL-BEING PARAMETERS IN THE INDOOR SPACES OF OFFICE BUILDINGS. CASE STUDY

Journal Title: Present Environment and Sustainable Development - Year 2012, Vol 6, Issue 1

Abstract

This study highlights the variation values of several important microclimatic parameters inside an office building. This way, during one year time period, from February 2010 to February 2011,, we have recorded the natural wet temperature, the predicted mean vote – PMV, the predicted percent of dissatisfied people– PPD, WBGT indoor, WBGT outdoor, the draught risk, the luminous intensity and the sound level. Then, we could calculate the monthly, daily and hourly variation of these microclimatic and ambient comfort parameters. The recordings of the data were made by means of a microclimatic indoor station, a sound level meter and a light meter. The results helped us understand better how the values of these microclimatic parameters may influence the working conditions inside an office building, if the microclimate is one of thermal comfort or discomfort, or if it is beneficial or harmful to the development in good conditions of working activities within collective environments.

Authors and Affiliations

Nicoleta Ionac, Adrian-Cătălin Mihoc, Paula Tăbleţ

Keywords

Related Articles

RADIOMETRIC MEASUREMENTS IN EASTERN MOLDAVIA.CORRELATIONS BETWEEN TOTAL CLOUDINESS AND THE SUNSHINE DURATION

Because during a period of time with clear sky, a maximum of solar radiation is obtained, it is obvious that the degree of sky coverage and the cloud type influence the sunshine duration and thus solar radiation (global...

ECOLOGIC REHABILITATION OF MINING SITES IN THE SUCEAVA COUNTY

Pollution and the risk of human communities or natural ecosystems from the mining sites do not disappear at the same time with the cessation of exploitation and useful mineral substances preparation activities. The respe...

SOME CONSEQUENCES OF THE FLOODS OF THE YEAR 2005 ON THE POPULATION AND THE SETTLEMENTS OF DÂMBOVIŢA COUNTY

L’an 2005 a été, pour la Roumanie, un an avec un grand nombre de phénomènes météorologiques dangereux, dont les plus importants ont été les inondations et les limons apparus dans la majorité des bassins hydrographiques d...

ENDOSULFAN RESISTANCE PROFILE OF SOIL BACTERIA AND POTENTIAL APPLICATION OF RESISTANT STRAINS IN BIOREMEDIATION

In the present study, bacterial strains were isolated from the soils of Wayanad District, Kerala, India and the isolates were tested for their tolerance to endosulfan and potential in bioremediation technology. Pesticide...

SOME THERMIC DIFFERENCES IN THE SOUTHERN METROPOLITAN AREA OF IAŞI

The regime of air temperature in the Iaşi municipality and the metropolitan area is a complex one, highlighted by the particularities of the average annual temperature, soil temperature, average monthly temperature, the...

Download PDF file
  • EP ID EP115900
  • DOI -
  • Views 105
  • Downloads 0

How To Cite

Nicoleta Ionac, Adrian-Cătălin Mihoc, Paula Tăbleţ (2012). AMBIENT WELL-BEING PARAMETERS IN THE INDOOR SPACES OF OFFICE BUILDINGS. CASE STUDY. Present Environment and Sustainable Development, 6(1), 81-93. https://www.europub.co.uk/articles/-A-115900