An Analytical- empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams

Journal Title: Journal of Biomedical Physics and Engineering - Year 2017, Vol 7, Issue 3

Abstract

Background: In this study, a method for linear attenuation coefficient calculation was introduced. Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury. Results: The values of calculated linear attenuation coefficient with this new method are in acceptable range. Also, the linear attenuation coefficient decreases slightly as the thickness of attenuating filter (Cerrobend or mercury) increased, so the procedure of linear attenuation coefficient variation is in agreement with other documents. The results showed that the attenuation ability of mercury was about 1.44 times more than Cerrobend. Conclusions: The method that was introduced in this study for linear attenuation coefficient calculation is general enough to treat beam modifiers with any shape or material by using the same formalism; however, calculating was made only for mercury and Cerrobend attenuator. On the other hand, it seems that this method is suitable for high energy shields or protector designing.

Authors and Affiliations

F Seif, M J Tahmasebi-Birgani, M R Bayatiani

Keywords

Related Articles

Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer

Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characteriza...

Design and Production of Two-piece Thyroid-neck Phantom by the Concurrent Use of Epoxy Resin and Poly(methyl methacrylate) Soft Tissue Equivalent Materials

The aim of this report is to present a new two-piece thyroid-neck phantom produced by the concurrent use of epoxy resin and poly(methyl methacrylate) (PMMA: plexiglass) soft tissue equivalent materials. Accordingly, mass...

“Triple M” Effect: A Proposed Mechanism to Explain Increased Dental Amalgam Microleakage after Exposure to Radiofrequency Electromagnetic Radiation

A large body of evidence now indicates that the amount of mercury released from dental amalgam fillings can be significantly accelerated by exposure to radiofrequency electromagnetic fields (RF-EMFs) such as common mobil...

Smart Phone Acceptance among Physicians: Application of Structural Equation Modelling in the Largest Iranian University

Background: The present study aimed to determine attitudes and effective factors in the acceptance of smart phones by physicians of the largest University of Medical Sciences in the south of Iran. Methods: This cross-se...

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may n...

Download PDF file
  • EP ID EP331729
  • DOI -
  • Views 90
  • Downloads 0

How To Cite

F Seif, M J Tahmasebi-Birgani, M R Bayatiani (2017). An Analytical- empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams. Journal of Biomedical Physics and Engineering, 7(3), 225-232. https://www.europub.co.uk/articles/-A-331729