Analysis and Evaluation of External Gap Line Arrester Performance in Transmission Lines without Shielding Wire under the Effect of Lightning and Ground Parameters

Journal Title: Applied Electromagnetics - Year 2022, Vol 10, Issue 2

Abstract

Surge arresters are used to protection of high voltage equipment and power transmission lines. Due to the presence or absence of shielding wire in transmission lines, surge arresters play an important role in reducing overvoltages. In this paper, the performance of an external gap arrester is investigated by considering different values of ground resistance and also the effect of soil ionization. The effect of lightning strike parameters such as rise time and tail time on overvoltage, insulator failure and energy absorbed in surge arrester for 63 kV transmission line without shielding wire has been simulated and studied in EMTP-ATP software. Considering the effect of the ground system, the use of external gap line arresters has provided better results compared to conventional arresters. Also, the surge arresters in the transmission line with shielding wire have a different operation from the transmission line without it. The results show that the surge arrester with an external gap compared to the surge arrester without gap has a better protective performance in absorbing energy and reducing overvoltage in this type of transmission line.

Authors and Affiliations

Seyyed Meysam Seyyedbarzegar

Keywords

Related Articles

Examination and simulation of the electromagnetic impact on electronic components

Sensors are one of the most vulnerable electronic devices to high-power electromagnetic waves such as (HPEM), (UWB), and (EMP). To achieve such effects, a model of the effect of electromagnetic interference has been prop...

Theoretical study of hole structure and core size on the gap-map of hollow-core photonic crystal fiber

Light propagating in the hollow-core photonic crystal fiber is based on the photonic band-gap (PBG) structures. Triangular and honeycomb structures are sub-structure of the alternating hexagonal structure. In this paper,...

Magnetic Anomaly Detection Method with Empirical Mode Decomposition and Minimum Entropy Feature

Abstract: Magnetic anomaly detection (MAD) is a passive method for airborne detection of subsurface objects. Light, radar and sound waves are unable to pass through the open air into the sea water environment and penetra...

Investigation of length reduction and radiation power enhancement of short-wavelength free electron laser

Free electron laser technology is one of the most suitable options to achieve high power, coherent radiation in the range of short wavelengths, especially XUV and X. One of the most important challenges in construction o...

Numerical Evaluation of Electrohydrodynamic Flow and Particle Concentration Effects on the Wire-Plate Electrostatic Precipitator Efficiency

In this paper, a two-dimensional computational model is implemented to study all the necessary phenomena in a simple one-stage plane depositor by considering the interactions between the electrostatic field, the flow fie...

Download PDF file
  • EP ID EP731166
  • DOI -
  • Views 72
  • Downloads 0

How To Cite

Seyyed Meysam Seyyedbarzegar (2022). Analysis and Evaluation of External Gap Line Arrester Performance in Transmission Lines without Shielding Wire under the Effect of Lightning and Ground Parameters. Applied Electromagnetics, 10(2), -. https://www.europub.co.uk/articles/-A-731166