Analysis of Imprecision in Incurred Sample Reanalysis for Small Molecules

Journal Title: The AAPS Journal - Year 2015, Vol 17, Issue 1

Abstract

Over the years, incurred sample (IS) reanalysis (ISR) has become a tool to confirm the reliability of bioanalytical measurements. The recommendation for ISR acceptance criterion for small molecules is at least 67% of ISR samples that have reanalyzed concentrations within 20% of their original concentrations when normalized to their means. To understand the relevance of the ISR acceptance criterion and sample size requirements, simulated ISR studies evaluated the probability of ISR studies passing the acceptance criterion (ISR pass rate) as a function of IS imprecision and sample size. When IS imprecision (percent coefficient of variation: %CV) is low (≤10 or 1–10% CV), high ISR pass rate (≥99%) is attained with <50 samples. At intermediate IS imprecision (e.g., 12% CV or 7–12% CV range), 80–160 samples are required for a high ISR pass rate. When IS imprecision is at the higher end of the acceptance limit, ISR pass rate decreases significantly, and increasing sample size fails to achieve high ISR pass rate. The effect of systematic bias (e.g., instability, interconversion) on ISR pass rate is strongly dependent on sample size at intermediate IS imprecision. The results provide an understanding of the effect of IS imprecision on ISR pass rates and a framework for selection of ISR sample sizes.

Authors and Affiliations

Sriram Subramaniam, Devvrat Patel, Barbara M. Davit, Dale P. Conner

Keywords

Related Articles

Effect of PEG Surface Conformation on Anticancer Activity and Blood Circulation of Nanoemulsions Loaded with Tocotrienol-Rich Fraction of Palm Oil

Tocotrienol-rich fraction of palm oil, which contains the isomers of vitamin E, was shown to possess potent anticancer activity against mammary adenocarcinoma cell lines. Its clinical use, however, is limited by poor ora...

Evaluation of the Microcentrifuge Dissolution Method as a Tool for Spray-Dried Dispersion

Although using spray-dried dispersions (SDDs) to improve the bioavailability of poorly water-soluble compounds has become a common practice in supporting the early phases of clinical studies, their performance evaluation...

Role of plasma lipoproteins in modifying the toxic effects of water-insoluble drugs: Studies with cyclosporine A

Lipoproteins are a heterogeneous population of macromolecular aggregates of lipids and proteins that are responsible for the transport of lipids through the vascular and extravascular fluids from their site of synthesis...

Use of anatomical and kinetic models in the evaluation of human food additive safety

Toxicological testing in animals is relied upon as a surrogate for clinical testing of most food additives. Both animal and human clinical test results are generally available for direct additives when high levels of exp...

Prediction of Solubility and Permeability Class Membership: Provisional BCS Classification of the World’s Top Oral Drugs

The Biopharmaceutics Classification System (BCS) categorizes drugs into one of four biopharmaceutical classes according to their water solubility and membrane permeability characteristics and broadly allows the predictio...

Download PDF file
  • EP ID EP680906
  • DOI  10.1208/s12248-014-9689-1
  • Views 62
  • Downloads 0

How To Cite

Sriram Subramaniam, Devvrat Patel, Barbara M. Davit, Dale P. Conner (2015). Analysis of Imprecision in Incurred Sample Reanalysis for Small Molecules. The AAPS Journal, 17(1), -. https://www.europub.co.uk/articles/-A-680906