Assessment of CO, CO2 and Suspended Particulate Matter Emissions

Journal Title: Leonardo Electronic Journal of Practices and Technologies - Year 2007, Vol 6, Issue 11

Abstract

The concentrations of carbon oxides (CO and CO2) and suspended particulate matter at Benue Cement Company (BCC) and Tse-Kucha community was investigated. Results obtained, shows that concentrations of carbon dioxide of 34.40ppm, 39.50 ppm, 48.50 ppm, 78.55 ppm, 65.25 ppm, 26.80 ppm and 29.5 ppm for quarry, raw mill, cement mill, Kiln, packing house, limestone stockpile and Tse-Kucha community respectively were below the maximum standard natural concentration of CO[sub]2[/sub] in atmosphere of 600ppm while concentrations of CO (1.25ppm - 4.00ppm) measured in all the sample stations were below the Nigerian Ambient Air Quality Standards (NAAQS) and WHO max limit of 10 ppm - 20 ppm for an 8-hourly average time. Lastly, the concentrations of suspended particulate matter of 375 μg/m[sup]3[/sup], 338 μg/m[sup]3[/sup] and 290 μg/m[sup]3[/sup] at the cement mill, packing house and raw mill respectively were also above the World Health Organization’s (WHO’s) Guidelines and Standards for Ambient Air Quality which stipulates a range of 150 μg/m[sup]3[/sup] to 230 μg/m[sup]3[/sup] for a 24- hourly average.

Authors and Affiliations

Bala ABDULKARIM, Timothy CHIROMA, Ternenge JOSEPH

Keywords

Related Articles

SQL Application for Periodic System of Elements

The paper presents SQL power of periodic system using for didactic aim. The article is based on a PHP application developed to present a periodic system in a form, which can be used for answer at different questions, whi...

Design of a Manually Operated Paper-Recycling Machine

A manually operated paper-recycling machine was designed and fabricated. This was done to enable waste paper conversion into useful product. The fabricated plant consists of six major component units that include the dis...

Characteristics of Wood ASH/OPC Concrete

The study presents the behaviour of wood ash / OPC concrete. Chemical analysis of wood ash, bulk density, sieve analysis and specific gravity of wood ash and aggregates, consistency, setting time and slump test of the fr...

Code Recognition Device for Automobile, a Panacea for Automobiles Theft

Code Recognition Device is a security device for automobiles. It responds only to the right sequence of codes that are keyed from the key pad. This closes the electrical circuitry of the automobile and enables it to star...

Comprehensive Case Study of Coals from Farcasesti Area

A statistical study of analysis results was made for lignite from the Fărcăşeşti area (Gorj County, Romania), exemplified for the eight characteristic properties, as moisture content (imbibitions and hygroscopic), volati...

Download PDF file
  • EP ID EP144493
  • DOI -
  • Views 100
  • Downloads 0

How To Cite

Bala ABDULKARIM, Timothy CHIROMA, Ternenge JOSEPH (2007). Assessment of CO, CO2 and Suspended Particulate Matter Emissions. Leonardo Electronic Journal of Practices and Technologies, 6(11), 109-116. https://www.europub.co.uk/articles/-A-144493