ASSESSMENT OF NATURAL VENTILATION SYSTEM FOR A TYPICAL RESIDENTIAL HOUSE IN POLAND

Journal Title: Civil and Environmental Engineering Reports - Year 2016, Vol 3, Issue 22

Abstract

The paper presents the research results of field measurements campaign of natural ventilation performance and effectiveness in a residential building. The building is located in the microclimate whose parameters differ significantly in relation to a representative weather station. The measurement system recorded climate parameters and the physical variables characterizing the air flow in the rooms within 14 days of the winter season. The measurement results showed that in spite of proper design and construction of the ventilation system, unfavorable microclimatic conditions that differed from the predicted ones caused significant reduction in the efficiency of the ventilation system. Also, during some time periods, external climate conditions caused an opposite air flow direction in the vent inlets and outlets, leading to a significant deterioration of air quality and thermal comfort measured by CO2 concentration and PMV index in a residential area.

Authors and Affiliations

Romana ANTCZAK-JARZĄBSKA, Marek KRZACZEK

Keywords

Related Articles

MONITORING OF LANDSLIDE AREAS WITH THE USE OF CONTEMPORARY METHODS OF MEASURING AND MAPPING

In recent years, there is an increase of landslide risk observed, which is associated with intensive anthropogenic activities and extreme weather conditions. Appropriate monitoring and proper development of measurements...

Comparison of the calculation results of heat exchange between a single-family building and the ground obtained with the quasi-stationary and 3-d transient models. Part 1: continuous heating mode

The paper provides comparative results of calculations of heat exchange between ground and typical residential buildings using simplified (quasi-stationary) and more accurate (transient, three-dimensional) methods. Such...

SHAKEDOWN ANALYSIS OF “SOIL-PILE FOUNDATION-FRAME” SYSTEM UNDER SEISMIC ACTION

In this article, the seismic shakedown FEM analysis of reinforced concrete and composite spatial frame structures on the deformable foundation, taking into account the elasticplastic and brittle behavior of structures el...

CHEMICO-BIOLOGICAL SEWAGE TREATMENT PLANTS FOR PE <= 9.999

Removal of nitrogen and phosphorus compounds is not required in the case of sewage treatment plants serving the settlement units of up to 9.999 citizens and not charging treated sewage into staying waters. Therefore, it...

Download PDF file
  • EP ID EP243228
  • DOI -
  • Views 113
  • Downloads 0

How To Cite

Romana ANTCZAK-JARZĄBSKA, Marek KRZACZEK (2016). ASSESSMENT OF NATURAL VENTILATION SYSTEM FOR A TYPICAL RESIDENTIAL HOUSE IN POLAND. Civil and Environmental Engineering Reports, 3(22), 25-44. https://www.europub.co.uk/articles/-A-243228