Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth
Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 9
Abstract
Introduction: Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These NiTi instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. Aim: To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Materials and Methods: Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. Results: No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. Conclusion: The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary teeth.
Authors and Affiliations
Lavanya Govindaraju, Ganesh Jeevanandan, EMG Subramanian
Gastric Tuberculous Ulcer Perforation Presenting as Acute Peritonitis
Abstract Koch’s bacillus infection is a rare cause of gastric ulcer. Gastric perforation associated with tuberculosis is extremely rarely presented as generalised peritonitis. A 39-year-old patient presented with epigast...
Detection of Compound Heterozygous Sickle Cell-b+ Thalassaemia in a Patient with Extreme Weakness, Mild Jaundice and Moderate Anaemia - A Case Report
A 16-year-old female complained of extreme weakness. She had moderate anaemia; her Haemoglobin (Hb) was 7.7 gm/dl. Peripheral blood smear showed few sickled red cells. Sickle cell test was positive. High-Performance Liqu...
Disrupted Value System among Nursing Care Managers: A Qualitative Study
ABSTRACT Introduction: The degradation of moral and professional values and incompatibility between value and performance affects the individual’s value, and leads healthcare staff to completely abandon the profession. A...
A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India
Introduction: The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited info...
Platelet Rich Plasma as a Boon for Osteoarthritic Knees-A Prospective Observational Study
ABSTRACT Introduction: Knee pain is a leading cause of disability and the most prevalent form in the world. It is associated with tissue inflammation, physical disability and imbalanced homeostasis in cartilage. As the n...