Comparison between Two Endotracheal Tube Cuff Inflation Methods; Just-Seal Vs. Stethoscope-Guided

Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 6

Abstract

Introduction: The Endotracheal Tube (ETT) cuff performs a critical function of sealing the airway during positive pressure ventilation. There is a narrow range of cuff pressure required to maintain a functionally safe seal without exceeding capillary blood pressure. Aim: We aimed to compare Just-Seal (JS) and StethoscopeGuided (SG) method of ETT cuff inflation with respect to the volume of air required to inflate the cuff, the manometric cuff pressure achieved and also to assess for the occurrence of postoperative sore throat after extubation in both the groups. Materials and Methods: It was a prospective observational study done in a Tertiary Teaching Public Hospital over a period of 1½ years on 100 patients with 50 each in two groups; JS or SG method of cuff inflation. SPSS Version 17 was used for data analysis. Results: Statistically significant difference (p-value of less than 0.05) was noted between the two methods based on the volume of air injected into the cuff {the mean volume injected in JS was 6.79 ml and in the SG was 4.95 ml with p=5.71E-16 (< 0.05)} and cuff pressure achieved {mean cuff pressure achieved was 38.80 cm H2 O in the JS and 29.64 cm H2 O in SG with p=2.29E14 (< 0.05)}. The incidence of post extubation sore throat was 54% (27 in 50) in the JS group and only 12% (6 in 50) in the SG; p= 0.00000797. Conclusion: ETT cuff inflation guided by a stethoscope is an effective technique for ensuring appropriate cuff pressures thus accomplishing the objective of providing safe and superior quality care of the patient both during and after anaesthesia and reducing the likelihood of even minimal risk complications that may still have legal implications.

Authors and Affiliations

Rishiraj Borhazowal, Minal Harde, Rakesh Bhadade, Sona Dave, Swapnil Ganeshrao Aswa

Keywords

Related Articles

Evaluation of Salivary Cardiac Troponin-I as Potential Marker for Detection of Acute Myocardial Infarction

Introduction: Serum cardiac troponin-I is a specific biomarker and raised significantly after Myocardial Infarction. Saliva is a non-interventional bio-fluid which contains portion of serum constituents and can be key in...

Evaluation of Effect of Irrigants with or without Surfactant on Root Canal Transportation by Cone Beam Computed Tomography–An In vitro Study

Introduction: Maintenance of original canal anatomy with proper disinfection is our primary goal to achieve during root canal instrumentation. Surfactants are added to irrigating solution to promote deeper penetration in...

Congenital Ectropion Uveae with Glaucoma: A Case Report

Congenital Ectropion Uveae (CEU) is a rare anomaly characterised by ectropion uveae, iris hypoplasia, iridotrabecular dysgenesis and glaucoma. Hyperplasia of the iris pigment epithelium and its apparent spread over the a...

The Risk Factors for Development of Sepsis in Newborns with a Central Venous Catheter and their Association with the Serum Zinc Levels

ABSTRACT Introduction: Neonates with indwelling central venous catheters are at risk of developing the infection. Serum zinc plays a major role in mounting an immune response. Aim: To analyse the risk factors for develop...

Double Trouble in Systemic Sclerosis: Complete Heart Block and Systolic Dysfunction

ABSTRACT A 26-year-old female, a known case of diffuse systemic sclerosis present with multiple episodes of syncope and progressive dyspnoea over six months. Her electrocardiogram revealed complete heart block and left v...