Comparison of immersion ultrasound and low coherence reflectometry for ocular biometry in cataract patients
Journal Title: International Journal of Ophthalmology - Year 2018, Vol 11, Issue 6
Abstract
"AIM: To compare the results of axial length (AL) biometry in cataract eyes by three methods: immersion B-ultrasound (IB) biometry, immersion A-ultrasound (IA) biometry and optical low coherence reflectometry. METHODS: In this prospective observational study of eyes with cataract AL measurements were performed using immersion ultrasound and optical low coherence reflectometry device. The results were evaluated using Bland-Altman analyses. The differences between both methods were assessed using the paired t-test, and its correlation was evaluated by Pearson coefficient. RESULTS: Eighty eyes of 80 patients (39 men and 41 women) for cataract surgery were included in the study. The values of AL could be got from all 80 eyes by IB and IA, the difference of AL measurements between IA and IB was of no statistical significance (P=0.97); the mean difference in AL measurements was -0.031 mm (P=0.26; 95%CI, -0.09 to 0.02); linear regression showed an excellent correlation (r=0.98, P<0.0001). Forty-five of eighty eyes with results of AL measurements, which can be obtained by three methods; the difference of AL measurements was of no statistical significance (IA vs IB, P=0.18; IA vs Lenstar, P=0.51; IB vs Lenstar, P=0.07); linear regression showed an excellent correlation (IA vs IB, r=0.99; IA vs Lenstar, r=0.96; IB vs Lenstar, r=0.96); Bland-Altman analysis also showed good agreement between the two methods [IA vs IB, 95% limits of agreement (LoA), -0.36 to 0.28 mm; IA vs Lenstar, 95% LoA, -0.65 to 0.69 mm; IB vs Lenstar, 95% LoA, -0.55 to 0.68 mm]. CONCLUSION: Measurements with the optical low coherence reflectometry correlated well with IB and IA. In the eyes with serious refractive medium opacity, the measurements of AL could not be achieved or existed deviations when using optical low coherence reflectometry device. Under such circumstances, we should choose IA or IB as the optimization method to obtain measurements, in order to get much more accurate results."
Authors and Affiliations
Xiao-Yong Yuan
Efficacy of autologous conjunctival flap on repairing the late-onset filtering bleb leakage
"AIM: To evaluate the effectiveness of autologous conjunctival flap surgery for repairing the late-onset filtering bleb leakage after trabeculectomy. METHODS: This study retrospectively reviewed 106 eyes from 106 patient...
Disparate expression of autophagy in corneas of C57BL/6 mice and BALB/c mice after Aspergillus fumigatus infection
"AIM: To determine the disparate expression of autophagy in the Aspergillus fumigatus (A. fumigatus) keratitis between susceptible C57BL/6 mice and resistant BALB/c mice. METHODS: C57BL/6 and BALB/c mice were used to est...
Effects of contact lens wearing on keratoconus: a confocal microscopy observation
"AIM: To evaluate the corneal cell morphology of new keratoconus patients wearing two different types of rigid gas-permeable (RGP) contact lenses for 1y. METHODS: Thirty nine eyes of 39 new keratoconus patients were sele...
Uveal effusion following acute primary angle-closure: a retrospective case series
"AIM: To evaluate the morphological changes in anterior segment in Chinese patients with uveal effusion (UE) after the attack of acute primary angle-closure (APAC) using ultrasound biomicroscopy (UBM), and to assess the...
Retinal nerve fiber layer changes based on historic CD4 nadir among HIV positive patients undergoing glaucoma evaluation
"AIM: To determine relationships between retinal nerve fiber layer (RNFL) thickness and nadir CD4 cell count in human immunodeficiency virus (HIV) positive patients evaluated for glaucoma suspicion. METHODS: Data were re...