Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis
Journal Title: International Journal of Ophthalmology - Year 2018, Vol 11, Issue 4
Abstract
"AIM: To compare the optical quality after implantation of implantable collamer lens (ICL) and wavefront-guided laser in situ keratomileusis (WG-LASIK). METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index (OSI), the values of modulation transfer function (MTF) cutoff frequency, Strehl ratio, and the Optical Quality Analysis System (OQAS) values (OVs) were accessed. The higher order aberrations (HOAs) data including coma, trefoil, spherical, 2nd astigmatism and tetrafoil were also obtained. For patients with pupil size <6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded. RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent (P< 0.001). After the ICL implantation, the OSI decreased slightly from 2.34±1.92 to 2.24±1.18 with no statistical significance (P=0.62). While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively (Wilcoxon signed ranks test, P=0.000). None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mm-pupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2nd astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05, -0.04±0.04, 0.03±0.01 respectively (Wilcoxon signed ranks test, all P<0.05). At 6 mm-pupil, the induction of total HOAs was not statistically significant in the WG-LASIK group. CONCLUSION: ICL implantation has a less disturbance to optical quality than WG-LASIK. The OQAS is a valuable complementary measurement to the wavefront aberrometers in evaluating the optical quality."
Authors and Affiliations
Li Li
Prevalence and characteristics of peripheral myopic retinopathy in Guangzhou office workers
"AIM: To determine the prevalence and characteristics of peripheral myopic retinopathy among a sample of Guangzhou office workers. METHODS: A cross-sectional study of Guangzhou Chinese office works in different departmen...
Effect of body position on the pathogenesis of asymmetric primary open angle glaucoma
"AIM: To explore the pathogenesis of asymmetric primary open angle glaucoma (POAG) in both eyes by comparing the intraocular pressure (IOP) of patients who sleep in different positions and to investigate the relationship...
Corneal topographic changes and surgically induced astigmatism following combined phacoemulsification and 25-gauge vitrectomy
"AIM: To evaluate corneal topographic changes and surgically induced astigmatism (SIA) after combined phacoemulsification and 25-gauge transconjunctival sutureless vitrectomy (25-G TSV). METHODS: A retrospective study on...
XEN Gel Stent exposure 7mo after primary implantation: a case report
Letter to the Editor
Impact of ultrasound and optical biometry on refractive outcomes of cataract surgery after penetrating keratoplasty in keratoconus
"AIM: To analyse the impact of ultrasound and optical intraocular lens (IOL) calculation methods on refractive outcomes of cataract phacoemulsification performed after penetrating keratoplasty (PK) in keratoconus. METHOD...