Comparitive Evaluation of the Dimensional Accuracy of Multiple Casts Poured From Two Different Elastomeric Impression Materials

Journal Title: IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) - Year 2018, Vol 17, Issue 9

Abstract

Aim: The aim of the present study is to compare accuracy and dimensional stability of two different elastomeric impression materials, with respect to obtaining multiple casts at various times of pours. Materials and methods: A master die was prepared with specific dimension and impression was made using two different elastomeric impression materials and the impression was poured at various time periods. Casts thus obtained were evaluated under a CMM (Coordinate Measuring Machine) to evaluate various dimensional changes. Results: Addition silicones provided dies which were shorter in height and bigger in diameter in 2nd and 3rd pour. Condensation silicones showed insignificant changes from the master die at the Immediate pour but deteriorated rapidly after that in subsequent pours. Conclusion: None of the two impression material showed a consistent behavior up to the third pour They occasionally showed deviation from the pattern, but all these values were almost statistically insignificant.

Authors and Affiliations

Dr Sony Sebastian, DrKurien Varghese, DrBilaalSidhique Abubacker, DrJiji M Edakalathur

Keywords

.

Related Articles

Analysis of Radiological Parameters and Pirani Scoring In Management of Idiopathic Clubfeet by Ponseti Method

BACKGROUND : To final out agreement of association between radiological parameters and pirani scoring in management of idiopathic clubfeet corrected by ponseti method. METHOD : 50 patients of CTEV fulfilling criteria, at...

Burden and coping among caregivers of children with psychological disorders

Introduction: Children suffer from behavioural and mental illnesses like autism, hyperkinetic disorders, learning disorders, depression, anxiety disorders, conduct disorders, substance abuse, eating disorders and psychos...

Study of Prescribing Pattern in Pre-Eclampsia and Impact of Patient Education on Patient Adherence to Treatment

Preeclampsia is a form of hypertension that is unique to human pregnancy. It is the new onset of hypertension (≥140/90mmHg) with oedema or Proteinuria or both after 20 weeks of gestation. Based on this a non-invasive cro...

Post Operative Shivering: Prophylactic Effects of Ketamine and Pethidine, A Comparative Study in Tertiary Care Hospital.

Introduction: Postanesthetic shivering is one of the common problems following general anesthesia and an accompanying part of general anesthesia with different unpleasant and stressful consequences for patients undergoin...

Prevalence of Depression in Temporomandibular Joint Disorder: A Cross-Sectional Study

Background: Temporomandibular joint disorders (TMDs) causes a problem in chewing system which is comprised of the temporomandibular joint and soft tissue around it. Aim: The present study aimed to explore the relationshi...

Download PDF file
  • EP ID EP395393
  • DOI 10.9790/0853-1709070509.
  • Views 71
  • Downloads 0

How To Cite

Dr Sony Sebastian, DrKurien Varghese, DrBilaalSidhique Abubacker, DrJiji M Edakalathur (2018). Comparitive Evaluation of the Dimensional Accuracy of Multiple Casts Poured From Two Different Elastomeric Impression Materials. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS), 17(9), 5-9. https://www.europub.co.uk/articles/-A-395393