CYTOTOXICITY OF ENDODONTIC SEALERS-A COMPARATIVE STUDY USING L-929 MOUSE SKIN FIBROBLAST CELL RESPONSE-AN EX-VIVO STUDY

Abstract

Aim: The objective of the present research was to evaluate and to compare the cytotoxicity of four commonly used endodontic sealers Apexit Plus, AH plus, Sankin, and Endofloss. The cytotoxicity was evaluated after setting of the sealers at different time intervals. Materials and Methods: Mouse skin fibroblasts L-929 was obtained from cell repository centre of national centre for cell science Pune, India. The cells were grown as monolayer cultures in Dulbeccos Modified eagle Medium (DMEM). Each of the test materials were mixed according to the manufactures instruction and was allowed to set. 0.1ml of each of the set sealers was placed in the petriplates in direct contact with the fibroblasts at 24 and 48 hrs intervals and evaluated for cytotoxicity. The percentage viability of the fibroblasts were calculated and evaluated statistically. Results: The statistical analysis revealed that Apexit Plus showed slight to moderate toxicity at 24 and 48 hrs, when compared with other sealers. Sankin showed maximum toxicity at all time intervals. Conclusion: All tested endodontic sealers demonstrated varying amount of cytotoxicity at different time intervals. Apexit Plus showed the least amount of cytotoxicity and Sankin showed the highest level of cytotoxicity.

Authors and Affiliations

Dr. Aruna Kanaparthy| Assistant Professor, Department of Operative Dentistry, College of Dentistry, Jizan University , Jizan, Saudi Arabia, Email: draruna15@gmail.com, Dr. Rosaiah Kanaparthy| Assistant Professor, Dept of periodontics, College of Dentistry, Jizan University , Jizan, Saudi Arabia

Keywords

Related Articles

Microflaria in Pleural Effusion - An Atypical Presentation

Filariasis is a major public health problem in many areas of tropics and subtropics of Africa Western Pacifc, and parts of America affecting over 83 countries. It is a public health problem in India. The majority of cas...

THE USE OF PERITONEAL DIALYSIS IN THE MANAGEMENT OF PATIENTS WITH RENAL FAILURE AT INSTITUTE OF KIDNEY DISEASES, PESHAWAR

Peritoneal dialysis (PD) using an ordinary stylet cannula was studied in 253 patients (67% male and 33% female with age ranging from 3-67 years) suffering from renal failure. The study was conducted between January 2007...

Comparative Study Between the Effect of Myofascial Release Using M2T Blade and Kinesiotape on Recreational Badminton Shoulder Pain Subjects: A Randomised Clinical Trial

Background: Shoulder pain is one of the most common conditions seen in recreational badminton players. It is caused due to repeated movements at the shoulder joint which further limits the range of motion and hence hamp...

Comparative study on Virtual Reality Training (VRT) over Sensory Motor Training (SMT) in Unilateral Chronic Osteoarthritis – A Randomized Control Trial

Osteoarthritis is a common rheumatologic disease. Several non operative interventions have been described for the treatment. But the available evidences of comparing the effectiveness of Virtual reality training over se...

Effects of ankaferd blood stopper on soft tıssue healıng ın warfarın treated rats

Ankaferd Blood Stopper (ABS) is a new promising local haemostatic agent. Although there are many studies showing its mechanism of haemostasis, histological and biochemical effects of ABS have not been studied in detail....

Download PDF file
  • EP ID EP11567
  • DOI 10.5958/2319-5886.2016.00013.8
  • Views 298
  • Downloads 10

How To Cite

Dr. Aruna Kanaparthy, Dr. Rosaiah Kanaparthy (2016). CYTOTOXICITY OF ENDODONTIC SEALERS-A COMPARATIVE STUDY USING L-929 MOUSE SKIN FIBROBLAST CELL RESPONSE-AN EX-VIVO STUDY. International Journal of Medical Research & Health Sciences (IJMRHS), 5(1), 59-62. https://www.europub.co.uk/articles/-A-11567