Abstract

Objective To establish the internal quality control standard of leukocyte-depleted suspended red blood cell volume in our center, so as to guide the preparation of components, strengthen the internal quality control and improve the quality of blood preparations. Methods A total of 1 523 bags of whole blood collected using two manufacturers′ leukocyte-depleted blood bags from March to August 2023 at our center were extracted. The blood before and after filtration were weighed, and the volume of whole blood collected, the volume of filtration loss and the product volume based on the formula and measured specific gravity were calculated. According to the data distribution characteristics, the reference range of leukocyte-depleted suspended red blood cell volume was determined, and the differences of whole blood collection volume, filtration loss capacity and product capacity between the two manufacturers were analyzed. The quality control data of leukocyte-depleted red blood cells over the past year with the difference between another 100 bags of these cells and the reference interval were compared, and the effectiveness of reference interval was validated. Results The median whole blood collection volume in the sample size was 402.0 mL, with a median filtration loss of 42.4 mL, and an average volume of leukocyte-depleted suspended red blood cells at 322.5 mL. The whole blood collection volume (A: median 404.4 mL; B: median 397.7 mL, P<0.01) and the volume of leukocyte-depleted suspended red blood cell products (A: mean 331.4 mL; B: mean 312.0 mL, P<0.01) using manufacturer A′s leukocyte-depleted blood bag were both higher, with a lower filtration loss capacity (A: median 39.5 mL; B: median 46.6 mL, P<0.01). The standard deviation of the volume of leukocyte-depleted suspended red blood cell was 19.6, and the reference interval was 284.1-360.9 mL. The validation samples and quality control sampling data showed no difference from the interval samples (P>0.05). Conclusion According to the actual situation of our center, the volume standard of leukocyte-depleted suspended red blood cells in our center is determined to be 284.1-360.9 mL.

Authors and Affiliations

Xin CAO, Nana PING, Jin DING, Peng PENG, Na LIU, Yutong ZHANG, Na FENG

Keywords

Related Articles

Influence of sample hemolysis on ELISA test results in blood screening laboratory

Objective To analyze the effect of sample hemolysis on ELISA test results in blood screening laboratory, so as to determine the acceptable tolerance of hemolysis specific to laboratory test items and detection system, an...

Expert consensus on recipient blood type test and blood component transfusion after ABO-incompatibility hematopoietic stem cell transplantation

At present, ABO-incompatibility hematopoietic stem cell transplantation (ABOi-HSCT) accounts for 30%~50% of the total HSCT, and is no longer a major obstacle to HSCT. Transfusion therapy is an important treatment for HSC...

ABO blood group screening results among blood donors in Guangzhou from 2021 to 2022

Objective To investigate the distribution of ABO and RhD blood groups among voluntary blood donors in Guangzhou, in order to ensure clinical blood safety and better serve blood donors. Methods Routine ABO and RhD blood g...

HBV infection among blood donors from 18 domestic blood stations of prefecture-level cities

Objective To analyze the hepatitis B virus (HBV) infection data of blood donors from 18 domestic blood stations, so as to investigate the HBV infection situation of blood donors. Methods The positive rate of HBV and its...

Electrolyte changes induced by massive transfusion in patients undergoing cardiac surgery

Objective To investigate the effect of electrolyte concentration on transfusion related complications in patients undergoing cardiac surgery after short-term massive transfusion (MT). Methods Seventy-six cases of adult c...