Diagnosis of Contamination in Poland – Current State of Knowledge

Journal Title: Safety & Fire Technology - Year 2018, Vol 52, Issue 4

Abstract

Aim: The aim of this paper is to present the current state of knowledge on the reconnaissance of contamination in the automatic system by unmanned means. Introduction: The hypothetical threat of contamination in the territory of the Republic of Poland (RP) is growing. This threat may be caused by technological disasters and technical failures in industrial plants (including nuclear power plants) and also uncontrolled releases of highly toxic chemicals during transport, and in some cases, which cannot be ruled out, also by terrorism. This work introduces the dilemmas of the contamination reconnaissance system of the Polish Armed Forces, mainly their technical and organisational elements. It presents technical studies that have been used in NATO armies for the automated reconnaissance (detection) of contaminations. The basic operation of the system for the performance of its tasks is proposed. The implementation of automated systems would significantly increase the effectiveness of the Reconnaissance System of the Polish Armed Forces (SWS SZ RP), but also of other civil functional subsystems in the National Alert and Detection System (KSWSiA). Automated recognition systems have many advantages such as there being no need to expose staff to contamination and high mobility. Conclusions: There is a real threat that the territory of the Republic of Poland could become contaminated through the uncontrolled release of highly toxic chemicals from over 400 industrial plants that could be potential sources of major failures. Releases to the environment may be caused by natural factors (e.g. hurricanes, floods, earthquakes) or by unintentional (e.g. human error) or deliberate (e.g. act of terrorism) human activity. This analysis should not ignore threats posed by nuclear reactors located near the borders of the Republic of Poland and by pathogens. The Contamination Detection System of the Polish Armed Forces is incompatible in procedural terms with analogous solutions existing in NATO member states. In these countries it is preferable to use automated systems based on the latest technological developments, while in the Polish Armed Forces the systems employed are manually operated and obsolete. CBRN information management should be not only an instructional record, but a real element of the Chemical, Biological, Radiological and Nuclear Defence (CBRN Defence) system. The task involving risk assessment and forecasting should be an anticipatory task based on present inventory levels in plants and contribute to planning the deployment of the elements of the Contamination Detection System. The contamination reconnaissance system, modelled on the basis of the solutions available in NATO armies, should employ automatic means such as lidar, drones and robots or their joint implementation – drones with lidar, robots with lidar or dropped micro-pallets (with a set of sensors and a signal analysis and alerting system) with a specific service life (e.g. 24 h) – such as the US Organic Air Vehicle.

Authors and Affiliations

Władysław Harmata, Marek Witczak

Keywords

Related Articles

O wojnie i pokoju – dylematy polemologiczne

ABSTRAKT Cel: Celem artykułu jest przedstawienie zjawiska wojny i pokoju w kontekście polemologicznym. W artykule zaprezentowano wybrane pojęcia, definicje i teorie wojny oraz podjęto próbę identyfikacji wiedzy polemolog...

An Analysis of Water Supply System Requirements to Enhance Fire Safety in High Rise Residential Accommodation

Aim: The objective of this paper is to present the requirements of firefighting water supply systems with special focus on high residential buildings and firefighting equipment in such buildings, according to regulations...

Bariera powietrzna jako podział przestrzeni o charakterze liniowym w warunkach pożaru

Cel: Przedstawienie wyników badań własnych autorów w obszarze zastosowania barier powietrznych do wydzielenia obszarów niezadymionych w czasie pożaru w przestrzeniach o charakterze liniowym. Wyniki zaprezentowane w pracy...

Zagrożenia związane z wykorzystaniem bezzałogowych platform w służbach ratunkowo-porządkowych

Cel: Celem artykułu jest identyfikacja i przedstawienie najważniejszych zagrożeń związanych z coraz powszechniejszym stosowaniem platform bezzałogowych oraz metod i sposobów ich ograniczenia. Autorzy zaprezentowali zagro...

Analysis of Major Incidents Caused by Accidental Emission of Nitrogen Compounds

Aim: To understand the specifics associated with accidental release of nitrogen compounds through an overall analysis of content in tables prepared by the authors of this paper. The tables are based on...

Download PDF file
  • EP ID EP524367
  • DOI 10.12845/bitp.52.4.2018.2
  • Views 88
  • Downloads 0

How To Cite

Władysław Harmata, Marek Witczak (2018). Diagnosis of Contamination in Poland – Current State of Knowledge. Safety & Fire Technology, 52(4), 20-45. https://www.europub.co.uk/articles/-A-524367