Dimensional accuracy of die stone and die silicone an invitro comparative study

Journal Title: INTERNATIONAL JOURNAL OF CURRENT RESEARCH - Year 2018, Vol 10, Issue 4

Abstract

Background: Die for making indirect restoration is vital. Die silicone material is user friendly and fast. But does it compare to Die Stone in accuracy. Aim: to compare the accuracy of reproduction of details between Die stone and Die Silicone. Methods: A metal die with known dimensions is made. Impressions are made with Polyether impression material. Dies are made out of Die Stone and Die Silicone. The Dimensions of the reproduced details are measured and compared. Results: Both Die Stone and Die Silicone produce comparable results. Conclusion: As Die Silicone is fast setting and easy to use, when Dies are required at the earliest, like during making of indirect restoration on the Chairside, Die Silicone can be the material of choice.

Authors and Affiliations

Ramesh, A. S. and Dr. Vinoth Kumar, S.

Keywords

Related Articles

Fournier’s gangrene, fatal adverse event post medical male circumcision

Male circumcision has been shown to significantly reduce the risk of HIV infection through heterosexual intercourse by as much as 60% and medical male circumcision strategy was adopted as an additional prevention interve...

Re-emergence of influenza a (h1n1) virus as an epidemic agent among different age groups of patients in western Rajasthan (Jodhpur) India

Background: Influenza has a major impact on public health, annually affecting 15-20% of the global population. First outbreak of influenza as a pandemic declared by WHO in June 2009. Aim: This study was aimed to determi...

Post operative nausea vomiting (ponv): effect of ondansetron and palonosetron

The most common and distressing symptom following general anaesthesia are nausea and vomitting which occurs in post operative period of 20% to 30% of patients. The aim of this study is to compare the anti emetic eficacy...

Placental laterality detected by USG as predictor for the development of preeclampsia

Objective: To find out whether placental laterality as determined by ultrasound can be used as a predictor for development of preeclampsia. Methods: In this prospective study, a total of 200 singleton pregnant women atte...

Contemporary trends of drugs causing fixed drug eruptions

Background: The extensive outgrowth of newer drug molecules not only improves the disease condition but also frequently changes the pattern of Adverse Cutaneous Drug Reaction (ACDR). The need for this study is to identi...

Download PDF file
  • EP ID EP403402
  • DOI -
  • Views 120
  • Downloads 0

How To Cite

Ramesh, A. S. and Dr. Vinoth Kumar, S. (2018). Dimensional accuracy of die stone and die silicone an invitro comparative study. INTERNATIONAL JOURNAL OF CURRENT RESEARCH, 10(4), 67667-67670. https://www.europub.co.uk/articles/-A-403402