Dosimetry and Radioenhancement Comparison of Gold Nanoparticles in Kilovoltage and Megavoltage Radiotherapy using MAGAT Polymer Gel Dosimeter

Journal Title: Journal of Biomedical Physics and Engineering - Year 2019, Vol 9, Issue 2

Abstract

Background: Numerous unique characteristics of the nanosized gold, including high atomic number, low toxicity, and high biocompatibility make it one of the most appropriate nanostructures to boost radiotherapy efficacy. Many in-vivo and in-vitro investigations have indicated that gold nanoparticles (AuNPs) can significantly increase tumor injuries in low kilovoltage radiotherapy. While deep-lying tumors require much higher energy levels with greater penetration power, and investigations carried out in megavoltage energy range show contradictory results. Objective: In this study, we quantitatively assess and compare dose enhancement factors (DEFs) obtained through AuNPs under radiation of Cobalt-60 source (1.25MeV) versus Iridium-192 source (380 KeV) using MAGAT gel dosimeter. Material and Methods: MAGAT polymer gel in both pure and combined with 0.2 mM AuNPs was synthesized. In order to quantify the effect of energy on DEF, irradiation was carried out by Co-60 external radiotherapy and Ir-192 internal radiotherapy. Finally, readings of irradiated and non-irradiated gels were performed by MR imaging. Results: The radiation-induced R2 (1/T2) changes of the gel tubes doped with AuNPs compared to control samples, upon irradiation of beams released by Ir-192 source showed a significant dose enhancement (15.31% ±0.30) relative to the Co-60 external radiotherapy (5.85% ±0.14). Conclusion: This preliminary study suggests the feasibility of using AuNPs in radiation therapy (RT), especially in low-energy sources of brachytherapy. In addition, MAGAT polymer gel, as a powerful dosimeter, could be used for 3D visualization of radiation dose distribution of AuNPs in radiotherapy.

Authors and Affiliations

N. Riyahi Alam, S. Farahani, M. Khoobi, Gh. Geraily, E. Gorji

Keywords

Related Articles

Neural Network-Based Learning Kernel for Automatic Segmentation of Multiple Sclerosis Lesions on Magnetic Resonance Images

Background: Multiple Sclerosis (MS) is a degenerative disease of central nervous system. MS patients have some dead tissues in their brains called MS lesions. MRI is an imaging technique sensitive to soft tissues such as...

Diagnosis of OCD Patients Using Drawing Features of Bender Gestalt Shapes

Background: Since psychological tests such as questionnaire or drawing tests are almost qualitative, their results carry a degree of uncertainty and sometimes subjectivity. The deficiency of all drawing test is that the...

Correlation between Trunk-Pelvis InterSegmental Coordination Parameters during Walking and Disability Level in Chronic Low Back Pain Patients

Background: Chronic low back pain (CLBP) disability has been particularly frustrating because its treatment has been a great therapeutic challenge. Disability has been suggested to depend on different factors that should...

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated. Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. M...

Is Induction of Anomalies in Lymphocytes of the Residents of High Background Radiation Areas Associated with Increased Cancer Risk?

Man has been exposed to different levels of natural background radiation since the creation of human life. There are inhabited areas around the world with extraordinary levels of natural background radiation. The level o...

Download PDF file
  • EP ID EP613509
  • DOI -
  • Views 106
  • Downloads 0

How To Cite

N. Riyahi Alam, S. Farahani, M. Khoobi, Gh. Geraily, E. Gorji (2019). Dosimetry and Radioenhancement Comparison of Gold Nanoparticles in Kilovoltage and Megavoltage Radiotherapy using MAGAT Polymer Gel Dosimeter. Journal of Biomedical Physics and Engineering, 9(2), 199-210. https://www.europub.co.uk/articles/-A-613509