Effect of evaporator-condenser diameter ratio (d/D) on thermal performance of the tapering heat pipe with various heat sources

Abstract

<p class="MDPI17abstract">In the present study, a new tapering heat pipe design had been developed to enhance the thermal performances. Boiling visualization in the tapering heat pipe is investigated to provide the detailed information of bubbles nucleation. Experiment was conducted in the tapering heat pipe with variation of the evaporator (d) to condenser (D) diameter ratio. The values of d/D are varied at 1/1; 1/2; 1/3 and 1/4. Heat load was generated at the evaporator section using heater DC-Power supply at 30, 40 and 50 Watt. The visualization technique was developed by using a transparent glass tube and the images of boiling bubbles were captured by SLR camera. The glass tube inclination is 45° and integrated with the NI-9211 and c-DAQ 9271 module. K-type thermocouple was set at the evaporator and condenser sections for measurement of boiling temperatures in the tapering heat pipe. Based on the results, it can be noted that variations of heat load and diameter ratio (d/D) of the evaporator and condenser affect the size and shape of boiling bubbles, as well as the nucleation temperature on the tapering heat pipe. The heat transfer coefficient tends to increase at a heat load of 50 W and diameter ratio d/D=1/4.</p>

Authors and Affiliations

Sarip Sarip, Sudjito Soeparman, Lilis Yuliati, Moch. Agus Choiron

Keywords

Related Articles

Determining the parameters for connections among the elements of design of vehicles in terms of ergonomics and crew safety

<p>This paper reports a study into the working processes of the system «operator ‒ machine ‒ external environment» in land vehicles using the constructed mathematical model.</p><p>A significant effect has been determined...

Obtaining, studying the properties, and application of zirconium(IV) oxymethanesulfonate

<p>The author has investigated the process to obtain zirconium (IV) oxymethanesulfonate via the interaction between methane sulfonic acid (CH<sub>3</sub>SO<sub>3</sub>H) (MSA) and zirconium (IV) oxocarbonate (ZrOCO<sub>3...

Prediction of operability of the plate rolling rolls based on the mixed fracture mechanism

<p>Influence of fracture of the mixed nature on the life of rolls of plate-rolling mills was considered. This is important because the time of trouble-free operation of plate-rolling rolls significantly affects the cost...

A study of modeling of flue gas patterns with number and shape variations of the catalytic converter filter

Exhaust gas in motorized vehicles is the main source of air pollution in the environment. Pollution of motor vehicle exhaust can be reduced by paying attention to the maintenance system, modern engine control concepts, f...

Studying the mutual interaction of hydraulic characteristics of water­distributing pipelines and their spraying devices in the coolers at energy units

<p>This analytical study is based on the results from hydraulic tests of spray nozzles for the mixing (waterjet) steam condenser at a thermal power plant's turbo generator. The work was performed at the stage of launch o...

Download PDF file
  • EP ID EP528205
  • DOI 10.15587/1729-4061.2018.141812
  • Views 77
  • Downloads 0

How To Cite

Sarip Sarip, Sudjito Soeparman, Lilis Yuliati, Moch. Agus Choiron (2018). Effect of evaporator-condenser diameter ratio (d/D) on thermal performance of the tapering heat pipe with various heat sources. Восточно-Европейский журнал передовых технологий, 5(8), 52-57. https://www.europub.co.uk/articles/-A-528205