Effect of Nano Filler on Microhardness, Diametral Tensile Strength and Compressive Strength of Nano-Filled Glass Ionomer

Journal Title: International Journal of Dentistry and Oral Science (IJDOS) - Year 2017, Vol 4, Issue 2

Abstract

Aim: This study was designed to evaluate the microhardness, diametral tensile strength and compressive strength of a nano-filled glass ionomer restorative material in comparison with a resin modified and conventional glass ionomers. Materials and Methods: A total of 45 specimens were prepared from three types of glass ionomer restorative materials. Specimens were cured with a light curing unit according to the manufacturer’s instructions. The specimens were prepared using Teflon split molds with dimensions of 6 mm height and 4 mm diameter. Incremental curing in 3 layers, 2mm each were used. After curing, all specimens were immersed in distilled water for 24 hours. Microhardness test was done using a Vickers microhardness Tester with 25 gf load for 5 sec. Diametral tensile strength and compressive strength were measured using Intestron testing machine at cross-head speed of 50 gm/ sec until fracture. Results: There was a significant difference among the tested materials in all testing parameters. Ketac fil Aplicap exhibited the highest hardness value while Glass carbomer fil GCP has the lowest value while GC Fuji II LC showed intermediate micro-hardness value. GC Fuji II LC exhibited the highest diametral tensile and compressive strength values while Ketac Fil Plus Aplicap has the lowest values. Glass Carbomer Fil, GCP showed intermediate diametral tensile and compressive strength values. Conclusions: The nano-filled glass ionomer (Glass Carbomer Fil, GCP) exhibited the lowest hardness value, intermediate diametral tensile and compressive strength values.

Authors and Affiliations

Ibrahim M Hamouda

Keywords

Related Articles

Ketofol as a Balanced Anesthetic for Procedural Sedation and Analgesia (PSA) in the Obese Oral Surgery Patient: a Commentary

A hallmark of oral and maxillofacial surgery is the administration of sedation and general anesthesia in the office setting. As part of their training, oral surgeons are required to function as anesthesia residents for a...

Implant-Supported Fixed Dentures Versus Implant-assisted Over-Dentures: A Prospective Follow up Study of the ability of Prosthetic Rehabilitation in the Mandible to Achieve Patient satisfaction

Background: Clinical experiences showed that most patients prefer the fixed prosthetic replacement of their missing teeth over the removable modalities, therefore this study was conducted to compare implants survival rat...

Main Predictors of Root Canal Endodontical Treatment: Systematic Review

Introduction: Defective apical seals were identified as the main cause of failures in endodontic treatment, and several studies have emphasized the importance of adequate coronal sealing between sessions for successful e...

Central Odontogenic Fibroma Associated with Eruption Disturbance of a Permanent Incisor in a Six-Year-Old Girl

Dentists occasionally encounter unilocular radiolucent lesions that may be associated with a wide spectrum of conditions in the jaw. Central odontogenic fibroma (COF) is a rare fibroblastic neoplasm of the jaw, which pre...

The Pioneer Bridge: A Long-Term, Non-Invasive, Esthetic Composite Bonded Bridge for the Replacement of Anterior Teeth

Objectives: The purpose of this study was to evaluate the retentive strength of the Pioneer Resin Bonded Bridge design with no abutment teeth preparations in comparison to the standard Maryland Bridge design. Materials...

Download PDF file
  • EP ID EP324547
  • DOI 10.19070/2377-8075-1700082
  • Views 175
  • Downloads 0

How To Cite

Ibrahim M Hamouda (2017). Effect of Nano Filler on Microhardness, Diametral Tensile Strength and Compressive Strength of Nano-Filled Glass Ionomer. International Journal of Dentistry and Oral Science (IJDOS), 4(2), 413-417. https://www.europub.co.uk/articles/-A-324547