Emission and dispersion of gaseous pollution from exhaust shafts of copper mine
Journal Title: Civil and Environmental Engineering Reports - Year 2013, Vol 1, Issue 10
Abstract
The primary objective of the study was to determine the volumes of emission and dispersion of gaseous pollution from 3 exhaust shafts of a copper mine P-VII, SW-3 and SG-2. To calculate the volumes of emission and dispersion of SO2, NO2 and CO the KOMIN and RWW computer programs were applied. The conducted analysis of the calculations and computer simulation showed that the extent of the impact of emisson on the rural residential area situated in the nearest vicinity of the shaft site is insignificant. The observed exceedance of reference values occurred on the premises of KGHM Polska Miedź S.A. The computer simulation proved that the nature reserve 'Buczyna Jakubowska' situated 1.6 kms north-west of the nearest emitters belonging to the mine is not exposed to above-standard concentrations of SO2, NO2 and CO.<br/><br/>
Authors and Affiliations
M. Jasiewicz, O. Słobodzian-Ksenicz, S. Gromadecka
THERMAL RENOVATION OF BUILDINGS WITH THE USE OF STRAW - EUROPEAN EXPERIENCE
The selection of building materials to a huge extent shapes building impact on the environment. In the era of widespread awareness of health problems arising from toxicity of chemical substances, healthy and safe materia...
MODERNIZATION OF PUBLIC SPACE FLOOR AND ITS IMPACT ON AREA - THE EXAMPLE OF THE KOŚCIUSZKO SQUARE IN BIAŁYSTOK
The last 25 years have been in many Polish cities a period of intensive modernization and renewals of the existing public spaces. Most of all the resurfacing of the pavement and changing of street furniture have been hel...
Sobieski palace in Lublin after the assessment of the existing condition. Restoration and modernization project
The Palace, situated in Bernardyńska Street in Lublin, has a checkered history – it was, among others, mentioned in the vetting in 1661; then it was the Sobieski family's property for about 100 years. In the subsequent p...
POSSIBILITY OF WASTE MFC WITH Ni-Co CATALYST OF FUEL ELECTRODE
One of the problems with microbial fuel cells is a low current density of those energy sources. Nonetheless, it is possible to increase the current density by using the catalyst for fuel electrode (anode) - as long as a...
CONNECTION CAPACITY OF THE TRANSITION ZONE IN STEEL-CONCRETE HYBRID BEAM
The problem of transition zone of structural steel element connected to concrete is discussed in the following paper. This zone may be located for instance in specific bridge composite girder. In such case the composite...