Empirical formulae for calculating γ-ray detectors effective solid angle ratio

Journal Title: Journal of Radiology and Oncology - Year 2017, Vol 1, Issue 1

Abstract

Determination of the detector efficiency using volumetric cylindrical sources is very important in various scientific and industrial fields, especially in the field of quantitative analysis. To calculate the absolute activity of any sample, the full-energy peak efficiency (FEPE) of the detector is needed. By applying the efficiency transfer method, the FEPE of the detector would be determined easily without using the standard sources. This approach depends on two main factors. The first one, is the reference efficiency of the reference source, which is determined experimentally, and the second one, is the calculation of the effective solid angle ratio between the sample and the reference source geometries. This work introduces an empirical formula for calculating the second factor for using two different sizes of NaI(Tl) detectors. The validity of this empirical formula was successfully demonstrated by comparing the calculating values with the experimental values.

Authors and Affiliations

AM El Khatib, MS Badawi, MA Elzaher, MM Gouda, AA Thabet, MI Abbas, KS Almugren

Keywords

Related Articles

Photon Absorption characteristics of some selected Enzyme Inhibitors used in Cancer Research in the Energy range 1 keV-100 GeV

The absorption parameters such as total mass attenuation coefficients, molecular, atomic, and electronic cross sections, effective atomic numbers and electron densities were calculated for some selected enzyme inhibitors...

Which is the best? Palliative Radiation Therapy to Spleen or Splenectomy

Spleen is one of the most important organ of the reticuloendothelial system and coordinates the immune response. Splenectomy is performed for hypersplenism, and staging of hematological malignancy. In conservatively foll...

Metallic Ureteric Stents a cost-effective alternative in the management of Obstructed Distal Ureters

Management of obstruction of the distal-pelvic ureters by minimally invasive procedures such as antigrade or retrograde double “J” stents has generally been unsatisfactory. Corrective surgical procedures mandate long hos...

Investigation of radiation attenuation parameters of some drugs used in Chemotherapy in Wide Energy Region

Objectives: The aim of this study is to compute the radiation attenuation parameters such as mass attenuation coefficient, linear attenuation coefficient, half value layer, mean free path, and effective atomic number for...

Clinically and Radiological isolated syndrome (MS risk)

Background: The use of brain magnetic resonance imaging (MRI) for evaluation of neurological disorders has increased in the past two decades. This has led to an increased detection of incidental findings on brain MRI. Th...

Download PDF file
  • EP ID EP541091
  • DOI 10.29328/journal.jro.1001002
  • Views 114
  • Downloads 0

How To Cite

AM El Khatib, MS Badawi, MA Elzaher, MM Gouda, AA Thabet, MI Abbas, KS Almugren (2017). Empirical formulae for calculating γ-ray detectors effective solid angle ratio. Journal of Radiology and Oncology, 1(1), 12-21. https://www.europub.co.uk/articles/-A-541091