Enhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound
Journal Title: Journal of Biomedical Physics and Engineering - Year 2017, Vol 7, Issue 2
Abstract
Background Hemodialysis is a process of removing waste and excess fluid from blood when kidneys cannot function efficiently. It often involves diverting blood to the filter of the dialysis machin to be cleared of toxic substances. Fouling of pores in dialysis membrane caused by adhesion of plasma protein and other toxins will reduce the efficacy of the filtre. Objectives In This study, the influence of pulsed ultrasound waves on diffusion and the prevention of fouling in the filter membrane were investigated. Methods Pulsed ultrasound waves with frequency of 1 MHz at an intensity of 1 W/cm2 was applied to the high flux (PES 130) filter. Blood and blood equivalent solutions were passed through the filter in separate experimental setups. The amount of Creatinine, Urea and Inulin cleared from both blood equvalent solution and human whole blood passed through High Flux (PES 130) filter were measured in the presence and absence of ultrasound irradiation. Samples were taken from the outlet of the dialyzer every five minutes and the clearance of each constituent was calculated. Results Statistical analysis of the blood equvalent solution and whole blood indicated the clearance of Urea and Inulin in the presence of ultrasound increased (p<0.05), while no significant effects were observed for Creatinine. Conclusions It may be concluded that ultrasound, as a mechanical force, can increase the rate of clearance of some toxins (such as middle and large molecules) in the hemodialysis process.
Authors and Affiliations
M B Shiran, M Barzegar Marvasti, A Shakeri-Zadeh, N Tabkhi, F Farkhondeh, E Kalantar
Adaptive Response Induced by Pre-Exposure to 915 MHz Radiofrequency: A Possible Role for Antioxidant Enzyme Activity
Background: Over the past few years, the rapid use of high frequency electromagnetic fields like mobile phones has raised global concerns about the negative health effects of its use. Adaptive response is the ability of...
Beam Collimation during Lumbar Spine Radiography: A Retrospective Study
Introduction: Collimating the primary beam to the area of diagnostic interest (ADI) has been strongly recommended as an effective method to reduce patient’s radiation dose and to improve image quality during radiology pr...
Comparison of Radiobiological Models for Radiation Therapy Plans of Prostate Cancer: Three-dimensional Conformal versus Intensity Modulated Radiation Therapy
Purpose: In the current study, using different radiobiological models, tumor control probability (TCP) and normal tissue complication probability (NTCP) of radiotherapy plans were calculated for three-dimensional conform...
Evaluation of Blood Parameters Alteration Following Low-dose Radiation Induced by Myocardial Perfusion Imaging
Introduction: With increasing the usage of myocardial perfusion imaging (MPI) for the diagnosis of ischemic heart disease, we aimed to evaluate the side effects of low-dose radiation induced by this technique on blood el...
An Investigation to Determine an Optimum Protective Garment Material in Nuclear Medicine
Aim: The aim of this study is to find an optimum material to protect garment for protection against 99Tcm radionuclide. Materials and Methods: Monte Carlo simulation code was applied to investigate radiation attenuation...