Evaluating the Performance of Unified Power Flow Controller (UPFC) On Fault Current Limitation in the Nigrian 330kv Power System.

Abstract

The Performance of Unified Power Flow Controller (UPFC) on Fault Current Limitation in a 330kV Power Network. The SIMULINK model of the Nigerian 330kV system was developed and the model of the UPFC was developed and integrated into the power system model. Results from simulation carried out showed the versatility of the UPFC in the protective limitation of excessive fault current in the system. Evaluation carried out indicated that the UPFC achieved an effective average of 59.23% fault current limitation. This result was shown to have high impact for the protection of critical assets within the power system such as circuit breakers. At a fault impedance of 0.0001Ω, the UPFC provided a 45.81% protection margin for the type of high voltage circuit breakers used on the 330kV system. Apart from interrupting capacity of circuit breakers, this action of the UPFC would also help to increase the life expectancy of circuit breaker contacts between overhaul.

Authors and Affiliations

J. M. Aloh, U. C Ogbuefi, M. J. Mbunwe, T. C. Madueme

Keywords

Related Articles

Energy Meter Monitoring Over Internet of Things

The Existing domestic Energy meter reading systems universally exist many problems, such as difficulty in construction, too narrow bandwidth, too low rate, poor real time, not two way communication quickly etc. To solve...

Implementation of New Three Phase Modular Multilevel Inverter for Renewable Energy Applications

This project proposes a new three-phase modular multilevel inverter (MMLI) for renewable applications. The cascaded multilevel inverters are the most favourable topologies of multilevel converters. This project introduce...

UAV Heading Control in Windy and Turbulent Conditions Using Reinforcement Learning

Due to the high non-linearity and coupling of a system model in an Unmanned Aerial Vehicle, UAV, the control of the heading has been a challenging task especially under windy and turbulent conditions. In this paper an on...

Initial Development and Testing of Microcontroller-MQ2 Gas Sensorfor University Air Quality Monitoring

Typical air quality monitoring system involved the use of expensive instruments often accessed through the Philippines Department of Environment and Natural Resources (DENR), leading to limitedlocale based air quality mo...

Mathematical Modelling And Steady-State Simulation Study of Three Phase Squirrel Cage Induction Machine, Using The Dot Convention Technique for Magnetically Coupled Circuit.

This paper presents the mathematical modelling and simulation study of three phase squirrel cage induction machine. This is achieved, using the dot convention technique for magnetically coupled circuit applicable to circ...

Download PDF file
  • EP ID EP388415
  • DOI 10.9790/1676-1206016170.
  • Views 128
  • Downloads 0

How To Cite

J. M. Aloh, U. C Ogbuefi, M. J. Mbunwe, T. C. Madueme (2017). Evaluating the Performance of Unified Power Flow Controller (UPFC) On Fault Current Limitation in the Nigrian 330kv Power System.. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 12(6), 61-70. https://www.europub.co.uk/articles/-A-388415