Experimental Study of RHA Concrete
Journal Title: International Journal for Research in Applied Science and Engineering Technology (IJRASET) - Year 2015, Vol 3, Issue 2
Abstract
This paper summarizes the research work on the properties of Rice Husk Ash (RHA) when used as partial replacement for Ordinary Portland Cement (OPC) in concrete. OPC was replaced with RHA by weight at 0%, 5%, 7.5%, 10%, 15% and 20%. 0% replacement served as the control. Slump cone test was carried out on fresh concrete while Compressive Strength test was carried out on hardened 150mm concrete cubes after 7, 14 and 28 days curing in water. The results revealed that the slump cone increased as the percentage replacement of OPC with RHA increased. The compressive and tensile strength of the hardened concrete also increase with increasing OPC replacement with RHA. It is recommended that further studies be carried out to gather more facts about the suitability of partial replacement of OPC with RHA in concrete.
Authors and Affiliations
Chandraul Kirti, Singh Manindra Kumar, Saxena Anil Kumar, Arora T. R
Spectrophotometric Methods for the Estimation of Third and Fourth Generation Cephalosporins In Dosage Form
The proposed spectrophotometric methods are rapid, sensitive and reproducible for the analysis of cefdinir(A), and cefepime(B) in pharmaceutical dosage forms with short analysis time. The authors developed reagent for t...
Video Watermarking Based On Wavelet Packet Analysis for Various Attack
As the world has moved to the digital era, whole content the living being has been uploaded to the server over internet. People are now very much familiar with the internet and are using for every need. The transition f...
Achieving High Secure Data Storage in Cloud Computing
Nowadays, cloud computing has attained great prominence due to various reasons for instance, on demand resource sharing and online storage of data. It is a collection of shared pool of information, resources that makes...
Improvement of Shear Strength of Sandy Silt Soil by Mixing Optimum Percentage of Fly Ash: A Study
Strength of soil is very important parameter for any civil construction. Soft and weak soil is more liable to differential settlements, less shear strength and high compressibility. Hence it is necessary to check and im...
Condensation and Radiation Modeling Of an Automotive Headlamp
An automotive headlamp is disclosed to heat fluctuation together with low air exchange the chances of humidity entering the headlamp will therefore enhance the risk for condensation to form on the inner surface of the l...