Flexural Performance of Mortise-tenon Prestressed Bolt Joints in Prefabricated Station Structure

Journal Title: Urban Mass Transit - Year 2024, Vol 27, Issue 7

Abstract

Objective The rationality of joint structures is crucial for station safety. Therefore, it is necessary to study the enhancement effect of additional prestressing measures on the flexural performance of prefabricated station structure bolt joints. Method A refined finite element model of mortise-tenon prestressed joints using prestressed bolts is established. Through four-point bending loading, the influence of different bolt design parameters on the flexural bearing capacity of joints is analyzed. Result & Conclusion During the bending moment loading process, joints connected by prestressed bolts exhibit good overall integrity. Stress concentration on the handhole position on the concave-side component tension side leads to tensile failure of nearby concrete. The vertical displacement and joint-seam opening of prestressed bolt joints gradually decrease with increasing bolt diameter and length, and the reduction amplitude decreases as the bolt diameter and length increase. Setting bolt preload force can significantly improve the flexural capacity of the joints, with a noticeable effect on controlling the deformation of joint-seam opening. Recommendations to optimize design parameters for prestressed bolt diameter, length and preload force are proposed.

Authors and Affiliations

Yanwei ZANG, Changbao LIU, Tianyang ZHANG, Jiajia YAN, Bochuan WANG, Honggui DI

Keywords

Related Articles

Universal Standardization of Signal Vehicle Interfaces for Urban Rail Transit

Objective Upgrading and modifying signal system is difficult, costly and time-consuming, greatly affecting the line daily operation during its modification stage. In order to solve the above problem, the signal vehicle i...

Construction and Application of Index System for Safety Effectiveness Evaluation of Urban Rail Transit Line Maintenance Construction

Objective At present, there are relatively few studies on the safety assessment of maintenance and construction of urban rail transit operation lines. In order to reduce the operation safety risk of urban rail transit li...

Architecture Design Scheme of Signal Centralized Monitoring System Based on Cloud Computing Technology

[Objective] To meet the development needs of railway electricity work monitoring services and address issues such as high coupling degree, lengthy deployment time, and high construction and operational costs in conventio...

Prediction Method for Land Subsidence Induced by Foundation Pit Dewatering under Complex Conditions

[Objective] To study the land subsidence variation patterns induced by foundation pit dewatering under complex conditions, the deep foundation pit project at Nanjing Metro Line 5 Airport Road Station is taken as a case...

Airflow Organization Characteristics of Metro Train Passenger Compartment

[Objective] The comfort of airflow delivery in metro air-conditioning systems is a critical indicator for the performance measurement. To ensure passenger comfort, it is necessary to maintain the indoor temperature and...