Heating Test at Household Refrigerator Type URG-129 Base Standard Nasional Indonesia (SNI) 04-6292.2.24-2001 for Safety Requirement

Journal Title: ASIAN JOURNAL OF NATURAL & APPLIED SCIENCES - Year 2015, Vol 4, Issue 2

Abstract

Electrical appliance safety assurance is needed. In the electrical equipment in refrigerator URG-129 brand UCD Indonesian products required test activities increase the heat to determine the feasibility of the use. Standards referenced in the testing technique are the Indonesian National Standard (SNI-04-6292.2.24). The test results showed that the level of flatness of the temperature distribution occurs in the working area (2.8 ± 0.5) ° C to (10.8 ± 0.4) ° C and when setting thermostat in normal position with the cooling load of ± 16 liters. Ice maker room temperature refrigerant URG-129 is always above 0 ° C, then refrigerator not qualify heating test. Setting thermostat on hree conditions, normal, cold and very cold, refrigerator cannot meet the test SNI requirement, ice maker refrigerator room temperature is always above 0 ° C.

Authors and Affiliations

Ali Musyafa, Faisal W. , Ya’Umar , Heri Justiono

Keywords

Related Articles

  EFFECTS OF HEAD INJURY ON MEMORY

  The present study folds two objectives; such as, first objective was to investigate the effects of head injury on memory between the participants with head and without head injury and, second objective was to...

Risk Factors for Macrosomia and Neonatal Complication in the Provincial Hospital Mohamed V of Chefchaouen, Morocco

The aim of the present work was to identify the prevalence and risk factors for macrosomia plus their impact on Maternal and Foetal Outcome. This retrospective study was carried out in the Mohamed V provincial Hospital...

 ENERGY AND PERFORMANCE MODELING OF DATAFLOW APPLICATIONS ON MANY-CORE ARCHITECTURES

 Many-core processors will provide system developers on embedded platforms with the best means of achieving system flexibility, shorter time to market, longer device life cycles and overcome the hardware productivit...

 EFFECT OF FIBER LENGTH ON THE PHYSICAL AND MECHANICAL PROPERTIES OF RANDOM OREINTED, NONWOVEN SHORT BANANA (MUSA BALBISIANA) FIBRE /EPOXY COMPOSITE

 The effects of Banana fibre length on the physical and mechanical properties of banana fibre/epoxy composite were investigated. Five different samples were produced by varying the length of the fibre between 5mm...

DESTRUCTIVE OPERATIONS IN MODERN DAY OBSTETRICS IN A TERTIARY INSTITUTION: CASE REPORT ON CRANIOTOMY

A case of 19 year old booked primigravida lady at 39 weeks gestation, with obstructed labour , intrauterine fetal death and intrapartum eclampsia is presented. She had craniotomy and was discharged home on 4th post-oper...

Download PDF file
  • EP ID EP142996
  • DOI -
  • Views 84
  • Downloads 0

How To Cite

Ali Musyafa, Faisal W. , Ya’Umar, Heri Justiono (2015). Heating Test at Household Refrigerator Type URG-129 Base Standard Nasional Indonesia (SNI) 04-6292.2.24-2001 for Safety Requirement. ASIAN JOURNAL OF NATURAL & APPLIED SCIENCES, 4(2), 24-33. https://www.europub.co.uk/articles/-A-142996