Highly Crosslinked Polyethylene Tibial Post Fracture in the Unafflicted Limb of a Patient with Unilateral Lower Limb Poliomyelitis: A Case Report

Journal Title: Malaysian Orthopaedic Journal - Year 2019, Vol 13, Issue 1

Abstract

We present a unique case of tibial post fracture of a posterior-stabilised total knee arthroplasty (PS-TKA) using highly crosslinked polyethylene (HXLPE) in the unafflicted limb of a patient who had poliomyelitis. The tibial post is an upright structure perpendicular to the PE insert articular surface which articulates with the cam of the femoral component to prevent excessive posterior translation of the tibia. We explore the choice of PS polyethylene (PE) inserts in patients with neuromuscular disorders (NMD). A 74-year old gentleman presented with recurrent knee pain seven years after the index PS-TKA with HXLPE. The TKA was performed on the unafflicted left limb (contralateral to the weak side affected by poliomyelitis). The posterior drawer test was positive. During the single-stage revision surgery, the HXLPE tibial post was noted to be broken. The liner was replaced with a thicker non-HXLPE. The patient achieved an excellent outcome at one-year post-surgery. This is the first report of HXLPE tibial post fracture in the unaffected knee of a patient with NMD affecting the lower limb. The HXLPE’s reduced resistance to fatigue crack propagation might not be suitable in PS-TKA where there might be focal stress points on the tibial post, which was amplified in this case as it was the limb that the patient most depended on. When managing end-stage osteoarthritis with TKA in the unafflicted knee of a patient with NMD causing lower limb weakness, the selection of polyethylene material in PS-TKA may need more consideration than previously thought.

Authors and Affiliations

Lee WC, Wee LHJ

Keywords

Related Articles

Construct Failure in an Atypical Femoral Fracture treated with Intramedullary Nailing: A Case Report

The aim of this paper is to document a rare case of construct failure in a 68-year old Filipina who sustained an atypical femoral fracture (AFF) in her left subtrochanteric area. The patient previously had a 40-month his...

WHAT’S IN A NAME? (Writing the Author’s Name in Scientific Publications)

This analytical editorial is written to highlight and illustrate, with examples, the style, form and format generally adopted by Malaysian, regional and Western authors in scientific publications, and is not meant to be...

Clubfoot: The Treatment Outcome Using Quantitative Assessment of Deformity

Introduction: The recent trend in management of congenital idiopathic clubfoot tends towards conservative treatment. This study reviews the outcomes of treatment in our practice using the quantitative clubfoot assessment...

Calf Compartment Syndrome associated with the Use of an Intra-osseous Line in an Adult Patient: A Case Report

We present a case of a lower limb compartment syndrome associated with the use of an intra-osseous line inserted into the proximal tibia in an adult patient. An unconscious 59-year old male with multiple injuries present...

Role of Antibiotic Cement Coated Nailing in Infected Nonunion of Tibia

Introduction: Infected nonunion of long bones is a chronic debilitating disorder. It is more difficult to deal with when the implant used for internal fixation itself becomes a potential media for infection because of b...

Download PDF file
  • EP ID EP520251
  • DOI 10.5704/MOJ.1903.008
  • Views 129
  • Downloads 0

How To Cite

Lee WC, Wee LHJ (2019). Highly Crosslinked Polyethylene Tibial Post Fracture in the Unafflicted Limb of a Patient with Unilateral Lower Limb Poliomyelitis: A Case Report. Malaysian Orthopaedic Journal, 13(1), 42-44. https://www.europub.co.uk/articles/-A-520251