Internal Quality control Monitoring & Evaluation of Creatinine, Urea, Alanine aminotransferase and Inter-Laboratory Assessment of Some Haematological Parameters In Two Hospitals in Central Nigeria.

Journal Title: IOSR Journal of Applied Chemistry (IOSR-JAC) - Year 2018, Vol 11, Issue 10

Abstract

The integrity of quality control samples is important to both management of overall quality as well as to meeting requirements of proficiency testing.The study was done to assess the quality control monitoring and evaluation of creatinine,urea,alanine aminotransferaseand also for inter-laboratory studies of somehaematological parameters packed cell volume (PCV),Mean cell Volume (MCV)andmean corpuscular haemoglobin (MCH), in Nisa Premier Hospital Abuja and the Benue State University Teaching Hospital Makurdi,North central Nigeria.The quality control monitoring& evaluation were conducted for two consecutive months using the spectrophotometer(kenza240 TXbiolabo France),and the inter -laboratory studies was performed directly on blood samples at both locations using the Automated Haematology Analyzer (KX-21N Sysmex, USA).The results of quality control assessment showed that Trends (loss of reliability) and shifts (abrupt changes in the control mean) were noted in the results of this study. The results of inter-laboratory assessment of the haematological parameters shows that both imprecision and bias exist between both laboratories. Although imprecision values were generally in the range of “Acceptable to marginal performance”, the overall bias between laboratories was in the range: SDI >1.5 or SDI < -1.5; In this study, Warning signs were recorded but there was no cause for rejection of the analytical run exception of alanine aminotransferase.

Authors and Affiliations

Stephen I. Audu, Isah Jibrin, Maryam Jibrin S. , J. Mohammed, Martha E. Ogbole

Keywords

Related Articles

Side Chain Bromination of 4 – Nitro Toluene by an Electro Chemical Method

A simple method for the preparation of 4 – Nitro Benzyl Bromide from 4 – Nitro Toluene is reported. The electrolysis was carried out in a two compartment electrochemical cell fitted with graphite electrodes at Room Tempe...

Synthesis and Characterization of Chlorophenylthiazolocoumarinyl Hydrazides as Promising Antimicrobial and Anti-Inflammatory Agents

Recently the reports of resistance to antibacterial drugs have drastically increased. In the search of novel antimicrobial agents, green facile synthesis of substituted phenyl-thiazolocoumarinyl hydrazides was designed a...

Analytical Studies On Precision And Accuracy In Micro determination Of Pb(II), Cd(II),Cr(III)And Hg(II) With Modified Reagent EAB- CTAB

Analytical studies have been carried out by forming ternary complex between Eriochrome Azurol B, a Triphenylmethane dye; cationic surfactant Cetyl Trimethyl Ammonium Bromide CTAB; and some heavy metal ions mainly Cd(II),...

Newly developed method for determination Indomethacin using Phosphotungstic acid by continue flow injection analysis via homemade ISNAG-fluorimeter.

A new, simple, sensitive and fastdeveloped methodfor the determination of Indomethacinin pure form and drugs (tablets)by continuous flow injection diverged light. The method based on the reaction of the Indomethacin with...

Green Biosynthesis of Silver Nano Particles from Aegle Marmelos Aqueous Leaf Extract

Objectives: Eco friendly methods of green mediated synthesis of nanoparticles are the present research in the limb of nanotechnology. The biosynthesis of silver nanoparticles are done using dried leaves extract of Aegle...

Download PDF file
  • EP ID EP414410
  • DOI 10.9790/5736-1110010105.
  • Views 170
  • Downloads 0

How To Cite

Stephen I. Audu, Isah Jibrin, Maryam Jibrin S. , J. Mohammed, Martha E. Ogbole (2018). Internal Quality control Monitoring & Evaluation of Creatinine, Urea, Alanine aminotransferase and Inter-Laboratory Assessment of Some Haematological Parameters In Two Hospitals in Central Nigeria.. IOSR Journal of Applied Chemistry (IOSR-JAC), 11(10), 1-5. https://www.europub.co.uk/articles/-A-414410