Internal Soundproofing Buildings Isolated by Elastomeric Links from Externally Induced Vibration

Journal Title: Romanian Journal of Acoustics and Vibration - Year 2012, Vol 9, Issue 2

Abstract

Interior soundproofing is a requirement for buildings with special activities where the level of vibration and noise shall be minimal. This paper specifies the essential requirements for the definition of performance vibration isolation from the outside of buildings for special purposes. This category includes operating rooms, facilities and premises of "white rooms", rooms processing, calibration and mounting the semiconductor where the level of vibrations from the urban environment and/or industry should be below the allowed threshold. In this context, we detail the dynamic model of a building placed on elastomeric elements for which are set the physical and geometric conditions by decoupling and reduction their frequency in ratio 1/4 .... 1/6 of the excitation frequencies. Also, are set the equations of motion for the externally excited system in order to evaluate the level of forced vibrations.

Authors and Affiliations

Gabriela MINDU

Keywords

Related Articles

A Study on Free Vibration of Visco-elastic Tapered Plate with Clamped Ends

A mathematical analysis is presented here to analyze the free vibration of visco-elastic isotropic rectangular plate. The main objectives of the study are to assist engineers and scientists in designing of structures whi...

The Effect of the Internal Dissipation of the Energy in the Supports of Composite Neoprene used for the Basis Isolation under the Seismic Action

This work continues the researches who want to note the dissipated energy inside the viscoelastic materials harmonical excited. In this case we analyze the effect of the internal energy dissipation for the composite mate...

Diminution Noise and Vibration for Industrial Equipments Designated to Gearbox Testing

The paper refers to a complex algorithm of design test stands for gearboxes. The algorithm pursues the optimization of the complex assembly embodied by the stand. The optimization criteria point to minimizing power suppl...

Application for Automated Recognition of Damage Locations

This paper present an application developed in Visual Basic, able to precisely indicate a damage location for known beam characteristics (in terms of geometry and mechanical properties) and the natural frequencies of s...

Evaluation of the Dissipated Energy in Viscoelastic or Hysteretic Seismic Isolators

This paper represents the result of experimental and theoretical researches concerning the behaviour and the performance level specific to neoprene bearings subjected to conformity assessment. The tandardized test involv...

Download PDF file
  • EP ID EP109784
  • DOI -
  • Views 63
  • Downloads 0

How To Cite

Gabriela MINDU (2012). Internal Soundproofing Buildings Isolated by Elastomeric Links from Externally Induced Vibration. Romanian Journal of Acoustics and Vibration, 9(2), 131-133. https://www.europub.co.uk/articles/-A-109784