Intraoperative Corneal Incision Evaluation with Trypan Blue Technique

Journal Title: International Journal of Ophthalmology and Clinical Research - Year 2016, Vol 3, Issue 2

Abstract

In this report, we aimed to determine wound leakage by instillation of trypan blue onto main incision and side port incisions during phacoemulsification surgery with clear corneal incision technique. Thirty-four eyes with cataract of 34 patients, who were operated by phacoemulsification method were included in the study. Incision points were hydrated by balanced saline solution and leakage was controlled at the end of the surgery. Trypan test revealed minor leakage in 23 out of 34 eyes (67.6%). All of these leakages occurred at the side-port incisions. Trypan blue technique based on the logic of Seidel test seems to be an effective and simple method for demonstrating unnoticed wound leakages.

Authors and Affiliations

Keywords

Related Articles

Flash Visual Evoked Potential versus Pattern Visual Evoked Potential in the Diagnosis of Strabismic Amblyopia

Purpose: To compare the responses of flash visual evoked potential (FVEP) & pattern visual evoked potential (PVEP) in amblyopic eyes with the eyes of healthy children and to find out whether the flash VEP can help us in...

The Surgical Outcome of two Different Tear Drainage Tube in the Proximal Obstruction of Lacrimal System

Purpose: To evaluate the results of conjunctival dacryocystorhinostomy surgery with two different tear drainage tube. Methods: A total of 13 eyes of 13 patients (female 53.8%, male 46.2%) with persistent epiphora and se...

Intraoperative Corneal Incision Evaluation with Trypan Blue Technique

In this report, we aimed to determine wound leakage by instillation of trypan blue onto main incision and side port incisions during phacoemulsification surgery with clear corneal incision technique. Thirty-four eyes wit...

Haemophilus Influenzae Endophthalmitis Associated with a Glaucoma Drainage Implant in an Adult

Abstract: A 65-year-old male with primary open-angle glaucoma underwent tube shunt surgery with an Ahmed Glaucoma Valve FP-7 (New World Medical, Rancho Cucamonga, CA) in the left eye for uncontrolled intraocular pressure...

Role of Scheimpflug Imaging in the Diagnosis of Intraocular Lens Damage after Foldable Lens Implant: Case Report

To our knowledge, this is the only article that presents the Peak densitometry method of the Pentacam HR software as a tool for the diagnosis of intraocular lens damage after cataract surgery.

Download PDF file
  • EP ID EP341036
  • DOI 10.23937/2378-346X/1410050
  • Views 155
  • Downloads 0

How To Cite

(2016). Intraoperative Corneal Incision Evaluation with Trypan Blue Technique. International Journal of Ophthalmology and Clinical Research, 3(2), 1-2. https://www.europub.co.uk/articles/-A-341036