Investigation of Differential Pressure Flowmeters Accuracy in Pulsating Flows

Journal Title: Energy Engineering and Control Systems - Year 2016, Vol 2, Issue 1

Abstract

This work deals with the investigation of influence of flow pulsation on the accuracy of gas flowrate and volume measurement by means of the differential pressure flowmeters. Experimental studies of the step response curves of an impulse line with a pressure transducer (PT) were carried out with application of a high-frequency analog-to-digital converter of the pressure signal in the PT chamber. Mathematical model of an impulse line with a PT was built. This model provides simulation and investigation of the transient processes with high accuracy. The influence of the impulse line design (length, diameter) on the step response curves and on the frequency response curves as well as on the resonant frequency of the oscillating system (an impulse line with a PT chamber) was studied. The systematic errors of flowrate and volume measurement due to the resonance in the impulse lines which was caused by flow pulsation were simulated and studied for an acting differential pressure natural gas metering system. On the basis of the calculation results, it was defined that amplification of the amplitude of the oscillating signal of the differential pressure due to the resonance may lead to a negative systematic error of gas volume measurement. The systematic errors of gas flowrate and volume measurement caused by the flow pulsation can be reduced by choosing the correct design of the impulse lines in order to avoid the resonance.

Authors and Affiliations

Roman Fedoryshyn, Fedir Matiko, Ihor Kostyk, Yevhen Pistun

Keywords

Related Articles

Gas Dynamical Capillary Flowmeters of Small and Micro Flowrates of Gases

The possibility of application of glass capillary tubes (CTs) as sensors of small and micro flowrates of gases was justified. The accuracy of a number of CTs flowrate equations was analyzed on the basis of experimental s...

Method of Selecting the Speed of Jack Pump Driving Motor Based on Reservoir Flow Rate

The sucker-rod oil pumping unit productivity is influenced by lots of factors, including the operation mode of the jack pump electric drive system. Settings of the electric drive system affect the system’s energy indicat...

Research and Analysis of Rapidly Changing Gas Flow Temperatures Measurement Methods

The temperature of a transducer sensitive element, as a result of its heat capacity, will always lag behind the temperature of the gas flow if this temperature changes. When measuring the flow temperature that varies in...

High-Speed Computer Simulation of Electrical Circuits

The well-known numerical-analytic method based on zeroes/poles matching (as z-transform realization) of equivalent transfer function or complex impedance (conductivity) in Laplace domain was proposed for high-speed compu...

Influence of Parameters of Induction Motor-Centrifugal Pump Units with Hydropaths Connected in Series on their Modes

Using the mathematical model of the pump station power supply system in steady-state modes developed by the author, the influence of the parameters of induction motor-centrifugal pump units with in-series-connected hydro...

Download PDF file
  • EP ID EP256959
  • DOI 10.23939/jeecs2016.01.009
  • Views 92
  • Downloads 0

How To Cite

Roman Fedoryshyn, Fedir Matiko, Ihor Kostyk, Yevhen Pistun (2016). Investigation of Differential Pressure Flowmeters Accuracy in Pulsating Flows. Energy Engineering and Control Systems, 2(1), 9-18. https://www.europub.co.uk/articles/-A-256959