Laser Radiation Effects on Adenine
Journal Title: Journal of Nuclear Physics, Material Sciences, Radiation and Applications - Year 2018, Vol 6, Issue 1
Abstract
Laser interaction whit the gas phase nucleobase adenine is studied. A linear TOF mass spectrometer is utilized for measurements that require high mass resolution, high sensitivity, and sufficient ion yields of low mass fragment cations. The ion mass spectra are discussed at different laser energy intensities and two temperatures. In contrast to previous studies a number light ion is present in the mass spectra. The ion formation curves for 23 different ions are measured for the laser energy range from about 109 to 1010 W cm–2 and masses between 1 and 43 besides mass 57 which was present in the mass spectra and will be discuss. Data were taken heating the sample at 235o C. The number of 355nm absorbed photons was calculated accordingly to Keldysh theory and similar results were found using adenine -Ar mixture. Our results are compared with those reported formed by protons, electrons or multiple charged ions interactions. Different ions were found indicating the possible effect of multiphoton absorption.
Authors and Affiliations
L. X. Hallado , J. C. Poveda , E. Prieto , A. Guerrero , I. Álvarez , C. Cisneros
The Dependence of Surface Diffuseness Parameter on N/Z Ratio of The Fusion of Neutron-Rich Colliding Nuclei
Surface diffuseness parameter used in Woods-Saxon form of potential have been extracted from a large number of experimentally studied neutron-rich fusion cross sections at near barrier energies. The results of our system...
Laser Radiation Effects on Adenine
Laser interaction whit the gas phase nucleobase adenine is studied. A linear TOF mass spectrometer is utilized for measurements that require high mass resolution, high sensitivity, and sufficient ion yields of low mass f...
Temperature Effects in the Composition of Metal Halide Perovskite thin Films.
Metal halide perovskites have shown to be a structure with great promise as an efficient photovoltaic, but at the same time it is affected by instability problems that degrade their performance. Degradation mechanisms va...
Measurements of Neutrons In A Mixed GammaNeutron Field Using Three Different Types of Detectors
A linear electron accelerator for medical use is a device for the treatment of tumors by collimated beams of electrons and/or photons. These accelerators are devices that employ electromagnetic waves of high frequency, t...
Signal of h → µτ, ττ in ν2HDM⊕S3
Nowadays in particle physics, the exploration of the flavour physics through the Higgs boson phenomenology is one of the main goals in the field. In particular, we are interested in the Lepton Flavour Violation (LFV) pro...