Luminescent determination of residues of trazodon hydrochloride and melatonin after cleaning pharmaceutical equipment
Journal Title: Фармацевтичний журнал - Year 2019, Vol 4, Issue 4
Abstract
A prerequisite for ensuring the quality of medicines is their production in accordance with the rules of GMP (Good Manufacturing Practice for Medicinal Products), one of the most important requirements of which is equipment cleaning. In many cases, the same equipment is used in the production of various preparations. Therefore, to prevent contamination of each of the following drugs, the previous one, it is very important to carry out an effective equipment cleaning procedure with a mandatory assessment of its purity. The purpose of this study was to develop simple, express, selective methods for luminescent determination of residual quantities of APIs of trazodone hydrochloride (TG) and melatonin (MT) in washes to control the completeness of their removal when cleaning process equipment. The excitation and luminescence spectra were recorded using a Cary Eclipse "Varian" spectrofluorimeter (Australia) with a xenon lamp 150 W. Electronic absorption spectra were recorded on a UV-2401 PC spectrophotometer «Shimadzu» (Japan). The electronic absorption spectra of TG and MT have absorption bands in the UV spectral region. It was established experimentally that the excitation spectra of TG and MT are similar to their absorption spectra (λex = 318 nm (TG) and λem = 274 nm (MT)). The effect on the luminescence intensity of TG and MT of methanol, ethanol, acetonitrile, dimethylformamide, dimethylsulfoxide, propanol (50 v/v) was studied. It is established that the maximum luminescence is observed in water. The methods were validated according to the following parameters: specificity, linearity, accuracy, limit of quantitation. The degree of extraction of trazodone hydrochloride and melatonin from applicators and surfaces of pharmaceutical equipment is more than 90%. The developed methods can be recommended for determining the residual amounts of trazodone hydrochloride and melatonin while monitoring the quality of the cleaning of pharmaceutical equipment.
Authors and Affiliations
O. D. Voitiuk, A. V. Yegorova, Yu. V. Scrypynets, S. N. Kashutskуy, V. P. Antonovich
Pharmaceutical and medical law: control mode for the medicines for alcohol addiction pharmacotherapy
Prolonged alcohol abuse leads to an annual 2.5 million of deaths, generates negative social, economic and medical problems. Caused by alcohol, harm goes beyond the physical and mental health needs in the complex treatmen...
Pharmaceutical development with commercialization of generic drugs with poor soluble substance – tablets of drug nimodipine
The pharmaceutical development of solid dosage forms which containing a poor soluble substance deserves special attention, because a composition and a technology of production such drugs directly effects on release the a...
Human capital as a subject of social responsibility in a pharmaceutical organization
Today, great importance is attached to the implementation of pharmaceutical organizations proper social responsibility, which is aimed to the intellectualization of the main resource of the national economy i.e. human ca...
Antioxidant properties of hidazepam and amitriptyline with pain syndrome of rats
Peroxide modification of cell biostructures and functions due to the activation of free radical oxidative processes underlies the pathogenesis of a significant number of diseases different in its etiology. The ability of...
The development of standard of good pharmacy practice regarding the participation of pharmacists in public health
The change in the focus of healthcare in Ukraine from treatment to preventive medicine is necessary for improvement of medical and demographic situation in the country and the formation of a responsible attitude of citiz...