Management of Femoral Bone Defect after Gunshot Injury using Circular External Fixator

Journal Title: Journal of Pakistan Orthopaedic Association - Year 2018, Vol 30, Issue 01

Abstract

Objectives: Retrospective evaluation of healing index (HI) and consolidation time (CT) of gunshot femoral bone loss managed using conventional Ilizarov frame (CIF) versus Talyar Spatial Frame (TSF) fixator. Methods: This multicenter study included 15 patients had gunshot femoral bone loss of about 6 cm and average soft tissue defects of about 7 cm. External fixator was used in 9 patients, soft tissue defect was directly closed in 5 patients, using rotational flap in 5 patients, multiple Z-plasty in 2 patients and in 3 patients soft tissue defect was open managed and closed by secondary intention after application of CIF fixator. CIF fixator was used in 8 and TSF fixator in 7 patients. Mean latency period before starting distraction osteogenesis was 12.8±0.8; range: 12-14 days. Results: Mean distraction rate was 1.2±0.3 mm/day and inter-fragmentary compression rate was 0.25 mm/day for 5-7 days. Mean consolidation time was 97.8±18.1 days, and all patients had bone lengthening for a mean of 6.4±1.2 with a mean healing index of 15.3±1.37; range: 13.2-17.3. Patients categorized according to type of fixator showed non-significant (p>0.05) difference as regards clinical data. Conclusion: Distraction osteogenesis for gunshot femoral bone injuries could be achieved successfully using either Ilizarov or TSF circular fixator. Both fixators allowed bone lengthening within reasonable CT and with HI of about 15 days/cm.

Authors and Affiliations

Ibrahim Elsayed Abdellatif Abuomira1, Francesco Sala2, Mahmoud Mabrouk Said3, Ehab A. Abdalla Elshal1,Amar Abdelhalem Amar1

Keywords

Related Articles

To Determine Frequency of Radial Inclination in Normal Wrists of Local Population.

Objective: To determine the radial inclination in normal wrists of our local population Materials and Methods: This is a descriptive cross-sectional study that was conducted upon 100 volunteers in the orthopedic surge...

Traumatic Brachial Plexus Injuries: HULS Protocol of Management.

Objective:To determine the functional outcome of traumatic brachial plexus injuries managed in our institution with our own designated treatment protocol( Hand and Upper Limb Surgery-HULS). Methods:This descriptive st...

Causes of Neglected Clubfeet in Pakistan

Objective: To determine the causes of delay in treating clubfoot in our set up. Methods: This descriptive study was conducted from October 2015 and December 2018 in Hayatabad Medical Complex and Mercy Teaching Hospita...

Assessment of Incidence of Superbugs and Antibiotic Resistance in Orthopaedics, A Cross-Sectional Study

Objectives: Due to the presence of metallic implants, orthopedic surgeries are at increased risk of microbiological contamination and infection. Such infections require aggressive and prolonged use of antimicrobial thera...

Outcome of Schatzkar Type VI Tibial Plateau Fractures Treated with Ilizarov External Fixator

Objective: To analyze the results of schtzkar type VI tibial fractures treated with ilizarov external fixator. Methods: This study was conducted at Mardan Medical Complex from January 2015 to December 2017.All patient...

Download PDF file
  • EP ID EP741715
  • DOI -
  • Views 46
  • Downloads 0

How To Cite

Ibrahim Elsayed Abdellatif Abuomira1, Francesco Sala2, Mahmoud Mabrouk Said3, Ehab A. Abdalla Elshal1, Amar Abdelhalem Amar1 (2018). Management of Femoral Bone Defect after Gunshot Injury using Circular External Fixator. Journal of Pakistan Orthopaedic Association, 30(01), -. https://www.europub.co.uk/articles/-A-741715