Method for Uncertainty Evaluation of Vicarious Calibration of Spaceborne Visible to Near Infrared Radiometers

Abstract

A method for uncertainty evaluation of vicarious calibration for solar reflection channels (visible to near infrared) of spaceborne radiometers is proposed. Reflectance based at sensor radiance estimation method for solar reflection channels of radiometers onboard remote sensing satellites is also proposed. One of examples for vicarious calibration of LISA: Line Imager Space Application onboard LISAT: LAPAN-IPB Satellite is described. Through the preliminary analysis, it is found that the proposed uncertainty evaluation method is appropriate. Also, it is found that percent difference between DN: Digital Number derived radiance and estimated TOA: Top of the Atmosphere radiance (at sensor radiance) ranges from 3.5 to 9.6 %. It is also found that the percent difference at shorter wavelength (Blue) is greater than that of longer wavelength (Near Infrared: NIR). In comparison to those facts to those of Terra/ASTER/VNIR, it is natural and reasonable.

Authors and Affiliations

Kohei Arai, Wahyudi Hasbi, A Hadi Syafrudin, Patria Rachman Hakim, Sartika Salaswati, Lilik Budi Prasetyo, Yudi Setiawan

Keywords

Related Articles

Cloud Computing Auditing

Cloud Computing is a new form of IT system and infrastructure outsourcing as an alternative to traditional IT Outsourcing (ITO). Hence, migration to cloud computing is rapidly growing among organizations. Adopting this t...

Coverage-Aware Protocols in Wireless Sensor Networks: A Review

Coverage plays a vital role in wireless sensor networks (WSNs), since it is used as one of the important measure to achieve the performance of the sensor network. The sensor nodes in WSN have limited power and energy res...

Comparative Analysis of Support Vector Machine, Maximum Likelihood and Neural Network Classification on Multispectral Remote Sensing Data

Land cover classification is an essential process in many remote sensing applications. Classification based on supervised methods have been preferred by many due to its practicality, accuracy and objectivity compared to...

Multilevel Security Protocol using RFID

Though RFID provides automatic object identification, yet it is vulnerable to various security threats that put consumer and organization privacy at stake. In this work, we have considered some existing security protocol...

Implementation of Location Base Service on Tourism Places in West Nusa Tenggara by using Smartphone

The study is aimed to create an application that can assist users in finding information about tourism places in West Nusa Tenggara, Indonesia. West Nusa Tenggara is one of the provinces in Indonesia and one of the secon...

Download PDF file
  • EP ID EP448883
  • DOI 10.14569/IJACSA.2019.0100151
  • Views 89
  • Downloads 0

How To Cite

Kohei Arai, Wahyudi Hasbi, A Hadi Syafrudin, Patria Rachman Hakim, Sartika Salaswati, Lilik Budi Prasetyo, Yudi Setiawan (2019). Method for Uncertainty Evaluation of Vicarious Calibration of Spaceborne Visible to Near Infrared Radiometers. International Journal of Advanced Computer Science & Applications, 10(1), 387-393. https://www.europub.co.uk/articles/-A-448883