Molar characterization and analytical UPLC method development of matrix impurity, disregards impurity, specified impurity associated undetectable impurity of laboratory drug Isatin

Journal Title: Archives of Organic and Inorganic Chemical Sciences - Year 2018, Vol 3, Issue 4

Abstract

This is out line work on the process development for the impurity detection of Isatin from synthetic occurring and several new methods have been developed during the pursuit of this research. The article traces the evolution of various approaches and provides a comparison for overall efficiency. UPLC method has been developed and validated for simultaneous estimation of matrix impurity, disregards impurity; specified impurity associated undetectable impurity in pure synthetic formulations. Separation was carried out using column Hypersil ODS C18 (250 mm x 4.6mm x 5μm particle size) in isocratic mode using mobile phase composition pH 6.0 ammonium acetate Buffer: Acetonitrile (68:32) v/v and UV detection at 310 nm. The impurities were eluted at a flow rate of 1.0 mL/ min. The average retention times for matrix impurity, disregards impurity, specified impurity associated undetectable impurity were 2.86 and 3.67 min, 4.54 min respectively. The method was validated according to the ICH guidelines.

Authors and Affiliations

Rahul Hajare

Keywords

Related Articles

Crystal and Molecular Docking Studies of 3-[Bis-(2- Hydroxy-4,4-Dimethyl-6-Oxo-Cyclohex-1-Enyl)-Methyl]Benzonitrile with Focal Adhesion Kinase Inhibitors

Cyclohexane is found naturally to some extent in petroleum but is prepared commercially by catalytic hydrogenation of benzene.It is widely used as a solvent and in making certain compounds used in the preparation of nylo...

Emerging Trends in Coordination Polymers and Metal-Organic Frameworks: Perspectives, Synthesis, Properties and Applications

Coordination polymers including metal-organic frameworks, clathrates and cyanometallates have recently gained significance as an important class of solid state materials. In this critical review, the diversity, classific...

Kinetic Isotherm Studies of Azo Dyes by Metallic Oxide Nanoparticles Adsorbent

We reported the synthesis of Cu4O3 nanoparticles fabricated by Camellia Sinensis (green tea) leaves extract as reducing and stabilizing agent and studied the azo dyes removal efficiency. The formation of copper oxide nan...

Structures and Electrical Properties of Some Biologically Active Nucleic Acid Constituents

Zinc II, cadmium II and mercury II complexes derived from barbituric acid (BA), 5-nitrobarbituric acid (NBA), phenobarbital (PB) and 2-thiouracil (TU) were synthesized. The analytical results assigned the formation of co...

Metals Phytotoxicity Assessment and Phyto Maximum Allowable Concentration

Metals are significant environmental pollutants, and their toxicity is a problem of increasing significance for ecological, evolutionary, nutritional and environmental reasons Nagajyoti [1]; Bieby Voijant Tangahu [2]; Ma...

Download PDF file
  • EP ID EP603701
  • DOI 10.32474/AOICS.2018.03.000166
  • Views 54
  • Downloads 0

How To Cite

Rahul Hajare (2018). Molar characterization and analytical UPLC method development of matrix impurity, disregards impurity, specified impurity associated undetectable impurity of laboratory drug Isatin. Archives of Organic and Inorganic Chemical Sciences, 3(4), 374-376. https://www.europub.co.uk/articles/-A-603701