Monitoring the air fungal contamination load in two educational hospitals in Sanandaj, Iran

Journal Title: Journal of Advances in Environmental Health Research (JAEHR) - Year 2017, Vol 5, Issue 4

Abstract

Opportunistic fungal pathogens are known to increase infection in the health care workers and patients with immune deficiency. This study aimed to investigate the qualitative and quantitative airborne fungal contamination load in two Sanandaj hospitals. In this cross-sectional study, 112 biological samples from 15 different hospital wards were collected for 6 months by using the single-stage Anderson sampler in Sabouraud’s dextrose agar. Data were analyzed for the descriptive and analytical tests using IBMSPSS V.21 software and the air fungal contamination load (AFCL) was calculated (cfu/m3). The average hospital AFCL in Besat and Tovhid was 21.13 and 14.51 cfu/m3, respectively. No statistically significant differences were observed between AFCL and relative humidity (RH) in the two hospital samples (p = 0.495) according to independent t-test, whereas this difference in the average temperature in the hospital wards was significant (p < 0.001). Highest AFCL was observed in the surgical ward for females (AFCL = 35.34 cfu/m3) and the lowest was observed in the surgical and urology wards (AFCL = 2.2 cfu/m3) in the two hospitals. The frequency of Penicillium was the maximum with 77.6 and 65.25% in the Besat and Tovhid hospitals, respectively. In wards such as oncology, gynecological surgery, and operating room, further studies are needed to better control environmental conditions and fungal contamination. Thus, utilizing highly efficient air purification systems and regular monitoring of the biological risk for both patient and health care employees is recommended.

Authors and Affiliations

Farzad Aala, Shadi Kohzadi, Ashkan Faridi, Khoroosh Javan, Mozhdeh Amiri, Delnia Ahmadnezhad, Jamshid Khoubi

Keywords

Related Articles

A study on corrosion and scaling potential of drinking water supply resources in rural areas of Sarvabad, west of Iran

Corrosion is a physicochemical reaction occurring between the metal and its surroundings, which usually has an electrochemical nature and results in changes in the properties of the metal. The corrosive water dissolves t...

Assessment of household reverse-osmosis systems in heavy metal and solute ion removal in real and synthetic samples

In this study, the efficiency of household reverse-osmosis system (HROS) with and without neutralizer accessory was investigated in both real and synthetic samples. The real samples were collected from rural and urban pu...

Chemical composition of indoor ash residues

The ash content formed after burning of materials in indoor may be harmful to environment on dumping due to high ionic and metallic concentration. Therefore, the chemical composition of various indoor ash residues derive...

Spatial distribution and analysis of heavy metal pollution in urban roadside dusts from Sanandaj, Iran

Industrial activities and high traffic density are the most important heavy metal pollution sources in urban areas. Roadside dust created by atmospheric deposition can be one of the best indicators for heavy metal contam...

System assessment and analysis of dangers in water safety plan: a case study in a desert city in Iran in 2017

Access to clean and safe drinking water has been the focus of officialsin charge of supplying water through many different methods. Water safety program is a new method for ensuring the safety of water by applying syst...

Download PDF file
  • EP ID EP425376
  • DOI 10.22102/jaehr.2018.84244.1019
  • Views 127
  • Downloads 0

How To Cite

Farzad Aala, Shadi Kohzadi, Ashkan Faridi, Khoroosh Javan, Mozhdeh Amiri, Delnia Ahmadnezhad, Jamshid Khoubi (2017). Monitoring the air fungal contamination load in two educational hospitals in Sanandaj, Iran. Journal of Advances in Environmental Health Research (JAEHR), 5(4), 233-240. https://www.europub.co.uk/articles/-A-425376