Dynamic Response Analysis of Automatic Generation Control in a 2-Area (Reheat & Non-Reheat) Interconnected Power System and a Scheme for Improvement of Response for the Same

Journal Title: International Journal of Modern Engineering Research (IJMER) - Year 2013, Vol 3, Issue 1

Abstract

 Abstract: In the present work, we focus on the study of dynamic behavior of an interconnected two-area power system and a scheme for improvement of response for the same. Here, two-area system with one non-reheat thermal units & one reheat thermal units is considered. The frequency and tie-line power deviation of two units are studied using MATLAB-SIMULINK in continuous time domain and also in discrete time domain. The paper focus on the study of frequency & tie-line power deviation for step load changes of 1% in both areas with conventional Proportional-Integral control and improvement in dynamic performances while replaced with discrete controller.

Authors and Affiliations

Er. Dipayan Guha

Keywords

Related Articles

[b][i]Dynamic Traffic Management Services to Provide High Performance in IntelRate Controller Using Fuzzy Logic[/i][/b]

Traffic is the chief puzzle problem in which every country faces to elaborate sending a mber of packets throughout the world. This paper proposes a new speculation for distributed traffic management by availing the...

 Stability of the Equilibrium Position of the Centre of Mass of an Inextensible Cable - Connected Satellites System in Circular Orbit

 In this paper we have studied the motion and stability of the centre of mass of a system of two satellites connected by inextensible cable under the influence of air resistance and magnetic force in the central g...

Simulation and Development of Stepper Motor for Badminton Playing Robot

The development of digital electronics and microprocessor systems has the advantage to the development of electric motor capable to be digitally controlled. In this paper stepper motor is used to control positi...

 Experimental Investigation of IC Engine and Gassifier with Different Biomass Materials

 Abstract: With recent price rise and scarcity of these fuels there has been a trend towards use of alternative energy sources like solar, wind, geothermal etc. However these energy resources have not been able to p...

 An Effective Strategy of Firewall Based Matching Algorithm

  Here the perimeter oriented to the network based strategy where the crossing of the traffic plays a major role in its implementation based aspect in a well oriented fashion respectively. Therefore there is a neces...

Download PDF file
  • EP ID EP151337
  • DOI -
  • Views 86
  • Downloads 0

How To Cite

Er. Dipayan Guha (2013).  Dynamic Response Analysis of Automatic Generation Control in a 2-Area (Reheat & Non-Reheat) Interconnected Power System and a Scheme for Improvement of Response for the Same. International Journal of Modern Engineering Research (IJMER), 3(1), 1-7. https://www.europub.co.uk/articles/-A-151337