Abstract

Background and rationale for the study. Limited studies have aimed to define the cut-offs of XL probe (XL cut-offs) for different stages of liver fibrosis, whereas those of M probe (M cut-offs) may not be applicable to XL probe. We aimed to derive appropriate XL cut-offs in overweight patients. Patients with liver stiffness measurement (LSM) by both probes were recruited. XL cut-offs probe for corresponding M cut-offs were derived from an exploratory cohort, and subsequently validated in a subgroup patients also underwent liver biopsy. The diagnostic accuracy of XL cut-offs to diagnose advanced fibrosis was evaluated. Results. Total 517 patients (63% male, mean age 58) who had reliable LSM by both probes were included in the exploratory cohort. There was a strong correlation between the LSM by M probe (LSM-M) and LSM by XL probe (LSM-XL) (r² = 0.89, p < 0.001). A decision tree using LSM-XL was learnt to predict the 3 categories of LSM-M (< 6.0kPa, 6.0-11.9kPa and ≥ 12.0kPa), and XL cut-offs at 4.8kPa and 10.7kPa were identified. These cut-offs were subsequently validated in a cohort of 147 patients who underwent liver biopsy. The overall accuracy was 89% among 62 patients whose LSM-XL < 4.8kPa or ≥ 10.7kPa. These cut-offs would have avoided under-staging of fibrosis among patients with body mass index (BMI) > 25-30 kg/m2 but not > 30 kg/m2. Conclusions. XL cut-offs at 4.8kPa and 10.7kPa were the best estimates of 6.0kPa and 12.0kPa of M probe for patients with BMI > 25-30 kg/m2. Patients with BMI > 30 kg/m² might use M probe cut-offs for XL probe.

Authors and Affiliations

Grace Wong, Julien Vergniol, Peter Lo, Vincent Wai-Sun Wong, Juliette Foucher, Brigitte Le Bail, Paul Cheung-Lung Choi, Faiza Chermak, Kwong-Sak Leung, Wassil Merrouche, Henry Lik-Yuen Chan, Victor de Lédinghen

Keywords

Related Articles

Gallstone disease and obesity: a population-based study on abdominal fat distribution and gender differences

Background. Existing evidence suggests the visceral fat is more metabolically active than subcutaneous fat. We aimed to investigate the value of subcutaneous (SAT) and visceral adipose tissue thickness (VAT) for predicti...

DNA methylation markers and serum α-fetoprotein level are prognostic factors in hepatocellular carcinoma

Introduction. Hypermethylation of relevant genes may affect the prognosis of patients with cancer. Thepurpose of this study was to analyze whether methylation of the promoter regions of cell cycle regulatorsas well as el...

Liver transplantation for autoimmune hepatitis in Peru: outcomes and recurrence

Background. Liver transplantation is the only therapy for end-stage liver disease. Cirrhosis secondary to autoimmune hepatitis (AIH) is an indication in 4-6% of adult transplants. Aims. To describe the outcomes and recur...

Potential Molecular Targets of Statins in the Prevention of Hepatocarcinogenesis

Hepatocellular carcinoma (HCC) represents 90% of liver tumors. Statins, may reduce the incidence of various tumors, including HCC. Antitumoral activities may be mediated by changes in transforming growth factor-beta (TGF...

Download PDF file
  • EP ID EP78301
  • DOI -
  • Views 130
  • Downloads 0

How To Cite

Grace Wong, Julien Vergniol, Peter Lo, Vincent Wai-Sun Wong, Juliette Foucher, Brigitte Le Bail, Paul Cheung-Lung Choi, Faiza Chermak, Kwong-Sak Leung, Wassil Merrouche, Henry Lik-Yuen Chan, Victor de Lédinghen (2013). Non-invasive assessment of liver fibrosis with transient elastography (FibroScan®): applying the cut-offs of M probe to XL probe. Annals of Hepatology, 12(4), 570-580. https://www.europub.co.uk/articles/-A-78301