Numerical Analysis of Arterial Plaque Thickness and its Impact on Artery Wall Compliance

Journal Title: Journal of Cardiovascular Medicine and Cardiology - Year 2015, Vol 2, Issue 2

Abstract

A numerical analysis was completed on the influence of plaque on the compliance of an artery wall. The analysis allowed a systematic variation of the transluminal pressure difference and plaque thickness. Included in the analysis was a sheath of surrounding tissue that provides support during the cyclical deformation. The analysis incorporated progressively thicker layers of plaque to quantify their impact on the artery compliance. It was found that the presence of plaque plays a significant role in reducing the compliance. It is also shown that modest reductions in plaque thickness can result in large changes in the compliance and a positive health outcome. The calculations also included only a health artery (absence of plaque). The healthy artery possessed the largest compliance of the cases. The healthy-artery results were compared with literature and found to be in good agreement. The calculations were made with four different transmural pressure variations to capture the entire range of possible values. The results for all pressure waveforms agreed qualitatively although there was some difference in magnitude.

Authors and Affiliations

LJ Vallez, B Sun, BD Plourde, JP Abraham, CS Staniloae

Keywords

Related Articles

Extraction of an Infected Active Fixation Coronary Sinus Lead with the Aid of a Tissue Stabilizer

We present a 49-year-old man who required extraction of a cardiac resynchronization device due to lead infection. While 2 leads were successfully retrieved by a transvenous approach the third one with active fixation and...

Disparity between estimates and measures of maximum heart rate in pilots with coronary artery disease

Background : Several studies indicate that HRmax estimates using the traditional equation, HRmax = 220 - Age, may represent a regression slope and intercept that does reflect the true relationship between age and maximal...

Effect of Scatter, Attenuation and Resolution Correction on a Pediatric Myocardial Perfusion SPECT Image

Scatter correction, attenuation correction, and resolution correction are commonly used to improve the quantify ability of a SPECT image. However, almost none of these are discussed specifically for the pediatric patient...

Cardiac Myxomas - Symptomology, Investigations and Surgical Treatment - Single Centre Experience of Fifteen Years at Grant Medical College, Mumbai, Maharashtra

Introduction: The aim of study is to describe the clinical symptoms, investigation findings and surgical treatment of cardiac myxomas. Method: From May 2002 to May 2017, 50 patients of primary or recurrent intracardiac m...

Sacubitril/Valsartan versus enalapril in nonischemic heart failure in Paradigm-Hf trial

Background: We compared the angiotensin receptor–neprilysin inhibitor LCZ696 (sacubitril/valsartan) with enalapril in patients who had nonischemic heart failure with a reduced ejection fraction. Methods: In this double-...

Download PDF file
  • EP ID EP231548
  • DOI 10.17352/2455-2976.000019
  • Views 75
  • Downloads 0

How To Cite

LJ Vallez, B Sun, BD Plourde, JP Abraham, CS Staniloae (2015). Numerical Analysis of Arterial Plaque Thickness and its Impact on Artery Wall Compliance. Journal of Cardiovascular Medicine and Cardiology, 2(2), 26-34. https://www.europub.co.uk/articles/-A-231548