NUMERICAL INVESTIGATION OF CAPILLARY TUBE BY REPLACING THE INSIDE REFRIGERANT AND DIAMETER

Abstract

The capillary tube used in the mostly in the refrigerant flow control devices. Hence performance of the capillary tube is best for good refrigerant flow. The many researchers had been concluding performance using experimentally, theoretically and analysis based. In this present work analyze the flow analysis of the refrigerant inside a capillary tube for adiabatic flow conditions. The proposed model can predict flow characteristics in adiabatic capillary tubes for a given mass flow rate. In the present work R-22 is replaced by Ammonia refrigerant has been used as a working fluid inside the capillary tube and the capillary tube design is changed straight to coiled capillary, which taken from good literature. The analysis is done in ANSYS CFX 16.2 software. It is observed from the results dryness fraction by using the helical capillary tube (Ammonia refrigerant flow) is better than straight and existing helical capillary tube (R22 refrigerant flow). The best suitable helical coiled design is suggested.

Authors and Affiliations

Abhinav Kulmitra

Keywords

Related Articles

 THE NEW THEORY OF THE ONENESS OF SQUARE AND CIRCLE

 Originally, Pi constant was understood as the ratio of circumference of a circle to its diameter. As the length of the circumference could not be measured due to its curvature, Exhaustion method was adopted for ma...

 OPTIMIZATION OF PEELING TIME AND OPERATIONAL SPEED FOR CASSAVA PEELING USING CENTRAL COMPOSITE DESIGN AND RESPONSE SURFACE METHODOLOGY

 The effect of two process parameters namely: peeling time and operational speed on the peeling process of cassava during cassava processing were investigated. The optimization of flesh loss from cassava was ca...

 Review Paper on Application of Variable Displacement Linkage in Radial Piston Pump

 Radial piston pumps are valve controlled with cylinders in a radial arrangement. The cylinder radials in one, two or several superimposed layers (stars) are driven by bearing fitted eccentrically on the drive shaf...

 High Order Differential Covariance based Source Separation of Monkey’s fMRI Data

 Blind source separation is a statistical technique in which an observed mixed data is decomposed in source signals and mixing channel. In BSS normally no, or little knowledge about the mixing channel is available...

BRAIN MACHINE INTERFACE SYSETM WITH ARTIFICIAL INTELLIGENT FOR A PERSON WITH DISABILITY

Brain Machine Interface (BMI) system is very useful modus operandi for the disabled or the crippled person to express his emotions and feelings to someone else with the help of EEG signals coming out of the brain. We...

Download PDF file
  • EP ID EP154264
  • DOI 10.5281/zenodo.56913
  • Views 107
  • Downloads 0

How To Cite

Abhinav Kulmitra (30). NUMERICAL INVESTIGATION OF CAPILLARY TUBE BY REPLACING THE INSIDE REFRIGERANT AND DIAMETER. International Journal of Engineering Sciences & Research Technology, 5(7), 102-114. https://www.europub.co.uk/articles/-A-154264