Optimal design and experimental study of Mg alloy electrodes for tissue welding
Journal Title: Progress in Medical Devices - Year 2025, Vol 3, Issue 1
Abstract
Objective: To investigate electrode weight reduction through structural modifications, focusing on variations in the thickness of circular electrodes to meet mechanical requirements. Additionally, optimal welding parameters were identified via experimental methods. Methods: Three electrode thicknesses were designed: 0.2 mm (T1), 0.3 mm (T2), and 0.4 mm (T3). The finite element method was used to analyze the stress, strain, and thermal effects on the surrounding tissue. In vitro tissue experiments assessed the mechanical strength of the anastomosis by measuring tear force and rupture pressure. Results: Among the three designs, the T3 electrode exhibited the lowest strain (1.2%) and stress (122.26 MPa). Thermal simulations showed maximum tissue damage of 53.3% and minimum damage of 48.6%. The maximum tear force (9.87±0.83 N) and rupture pressure (222.88±13.48 mmHg) were achieved with a compression force of 20 N, welding power of 160 W, and welding time of 8 seconds. Conclusion: T3 electrode demonstrated superior mechanical performance in the finite element analysis and successfully completed in vitro welding while minimizing electrode weight. Optimal welding parameters were identified.
Authors and Affiliations
Juxiao Wang, Lin Mao, Weiwei Fan, Chengli Song
Research progress on vascular clips for minimally invasive surgery
Minimally invasive surgeries are widely applied due to the advantages of small surgical wound, short postoperative recovery period, and low surgical infection rate. In minimally invasive surgery, vascular clips play a si...
A comprehensive review of spike sorting algorithms in neuroscience
Spike sorting plays a pivotal role in neuroscience, serving as a crucial step of separating electrical signals recorded from multiple neurons to further analyze neuronal interactions. This process involves separating ele...
Impact of tissue-electrode contact force on irreversible electroporation for atrial fibrillation in potato models
Background: Irreversible electroporation (IRE) is an emerging tissue ablation technique that offers advantages over traditional catheter ablation, such as minimal thermal damage and reduced treatment time. However, as th...
Overview of the current development in Visual-Inertial Systems
The Visual-inertial navigation system (VINS) integrates visual and inertial sensors, providing advanced navigation capabilities. Recent improvements in these sensors have made VINS widely applicable in areas such as robo...
Optimization design and performance study of magnesium alloy vascular clamp
Purpose: This study investigates the effects of varying inner diameter of a vascular clamp made from an Mg–Nd–Zn–Zr alloy on its functional performance. The primary objectives are to optimize the clamp’s structure, asses...