Optimization of Gamma Spectroscopy Setup for Am-Be based PGNAA Setup

Journal Title: International Journal of Engineering and Science Invention - Year 2017, Vol 6, Issue 12

Abstract

Gamma Spectroscopy setup is an integral part of prompt gamma activation setup. Gamma spectroscopy setup consists of a Canberra Coaxial HpGe semiconductor detector and a Canberra digital spectrum analyzer (DSA1000).The detector calibration measurement were carried out for energy range 59.5 keV to 4439.4 keV with standard gamma sources, natural background (40K and 208Tl) gammas and ambient gamma from of 241Am4Be neutron source. Full energy peak efficiency is estimated for the energy range 59.5 keV to 1332.49 keV. Important detector performance parameter like full width at half maximum (FWHM), full width at one tenth of maximum (FWTM), peak-to-Compton ratio and gain variation of conversion factor with amplifier gain were also estimated. Optimization of digital signal processing (DSP) parameters for digital MCA were also carried out.

Authors and Affiliations

Dalpat Meena, S. K. Gupta, H. S. Palsania, Narendra Jakhar, Naresh Chejara

Keywords

Related Articles

Review on the Role of Mathematical Modeling in Energy Sectors

Energy plays very important roles for social and economic development of a country. It increases technological, industrial and agricultural aspects of the country. The demand for energy is also increasing day by day. In...

E-Learning– Aglobal Learningconcept Outside Of the Class Roomfor Professional Development

The Present Educational System In Class Room Is Needed To Upgrade With Advance Technology. When We Look Back, The Distance Educational System Is Completely Depends On Limited Material And Sources. The E-Learning Pros Lik...

Effect of Process Parameters on Angular Error in Wire-EDM Taper Cutting of AISI D2 Tool Steel

WEDM Taper-cutting is a very unique machining process which can generate curved surfaces on work pieces and it is especially important in the manufacturing of tools that require draft angles. One of the most important ap...

Artificial Intelligence (AI)’s Role in Search Engine Optimization (SEO)

This article describes the relationship between AI and SEO, the ways in which SEO ranking factors can be enhanced using AI. Some aspects of AI are also discussed, along with few applications of AI in SEO areas are briefl...

Heavy Metals (As, Cd & Pb) Toxicity & Detection of These Metals in Ground Water Sample: A Review on Different Techniques

The main threats to living world are associated with the exposure to heavy metals like cadmium (Cd), lead (Pb), arsenic (As), zinc (Zn), manganese (Mn), copper (Cu), nickel (Ni), chromium (Cr) and mercury (Hg). Even thou...

Download PDF file
  • EP ID EP404153
  • DOI -
  • Views 90
  • Downloads 0

How To Cite

Dalpat Meena, S. K. Gupta, H. S. Palsania, Narendra Jakhar, Naresh Chejara (2017). Optimization of Gamma Spectroscopy Setup for Am-Be based PGNAA Setup. International Journal of Engineering and Science Invention, 6(12), 13-20. https://www.europub.co.uk/articles/-A-404153