OPTIMUM DESIGN AND ANALYSIS OF RECTANGULAR MICROCANTILEVER FOR HUMAN IMMUNODEFICIENCY VIRUS DETECTION

Journal Title: Journal of Biomedical and Pharmaceutical Research - Year 2014, Vol 3, Issue 5

Abstract

Microcantilever based sensors is a promising platform for sensors in various chemical and biological applications. Rectangular microcantilever is commonly used biosensing device for the detection of various disease detection target in biomedical applications .HIV is a virus which producing life threatening diseases which attacks the immune system. In this paper to detect HIV, various analyses performed on rectangular cantilever for optimum design to produces maximum total displacement due to attachment of HIV virus on the surface of the microcantilever. This study proposes a rectangular cantilever for the detection of HIV under static mode of operation. The analysis is performed by varying the length, width, thickness of the rectangular cantilever for getting maximum displacement for one HIV detection. The simulation results show the displacement of cantilever with number of HIV targeted on the cantilever. From this analysis rectangular cantilever with length 1000 μm, width 100 μm and thickness 0.5 μm produces maximum deflection of 1.632 x10-8 μm with respect to the force applied due to one virus of HIV. Hence it may be possible to detect the HIV virus in human by using proposed rectangular microcantilever sensor as it produces measurable deflection using recent read out methods.

Authors and Affiliations

Gopinath. P. G. | Research Scholar, Department of ECE, JNTUA, Anantapuramu, Andhra Pradesh, India., Dr. S. Aruna Mastani| Department of ECE, JNTUA, Anantapuramu, Andhra Pradesh, India., Dr. V. R. Anitha| Department of ECE, Sree Vidyanikethan Engg.College, Tirupathi, Andhra Pradesh, India

Keywords

Related Articles

Recent Advances in Novel Semisolid Dosage Forms: An Overview

Semisolids constitute a significant proportion of pharmaceutical dosage forms. They serve as carriers for drugs that are topically delivered by way of the skin, cornea, rectal tissue, nasal mucosa, vagina, buccal tissue,...

A RARE CASE REPORT OF GIANT CELL TUMOR IN THE BODY OF TALUS AND OUR MANAGEMENT

Giant cell tumor is described as neoplasm of undifferentiated mesenchymal stromal cells with presence of abundant, multi-nucleated giant cells. It is generally considered to be a benign tumor. Giant cell tumor rarely inv...

A STUDY FOR LINGUAL NERVE PROTECTION DURING EXTRACTION OF THIRD MOLAR USING LINGUAL REACTOR

Lingual nerve damage during surgical removal of third molar is most common nerve damage reported. Its incidence rate has been reported from 0.6 to as high as 22% in various studies conducted. Our aim was to study the eff...

An Approach Based on Advantages over Conventional System

The convenience of administration and improved patient compliance are important in the design of oral drug delivery system which remains the preferred route of drug delivery inspite of various disadvantages. Oral deliver...

Impact of Calcium-Vitamin D Supplements on the Dissolution Pattern of Ranitidine Hydrochloride Tablets: An in vitro Dissolution Study using UV Spectroscopy

The objective of this study was to evaluate the impact of Calcium-Vitamin D supplement formulations on the dissolution pattern of different Ranitidine Hydrochloride tablet formulations. This was an in-vitro dissolution s...

Download PDF file
  • EP ID EP3433
  • DOI -
  • Views 399
  • Downloads 18

How To Cite

Gopinath. P. G. , Dr. S. Aruna Mastani, Dr. V. R. Anitha (2014). OPTIMUM DESIGN AND ANALYSIS OF RECTANGULAR MICROCANTILEVER FOR HUMAN IMMUNODEFICIENCY VIRUS DETECTION. Journal of Biomedical and Pharmaceutical Research, 3(5), 50-54. https://www.europub.co.uk/articles/-A-3433