ORTHOGONAL COMPONENTS OF THE THREE-PHASE CURRENT AT ASYMMETRICAL ACTIVE-REACTIVE LOAD IN 4-WIRE CIRCUIT

Abstract

Purpose. For the unbalanced sinusoidal mode with asymmetric voltage in 3-phase 4-wire to receive the orthogonal 4-component decomposition of 3-phase current, are classified symmetry/asymmetry of active and reactive load elements separately. Methodology. The methodology is based on the vector approach, which with one voice allows to analyze the energy characteristics of a 4-wire and 3-wire circuits as balanced and unbalanced modes. At asymmetrical voltage the matrix representation methodology of the equivalent conductivities is used. Results. For 3-phase 4-wire network with a sinusoidal unbalanced mode with asymmetric voltage obtained 4-component orthogonal decomposition of the 3-phase current. The components have a clear electro-energetic sense and are classified irrespective by the load condition. Originality. The resulting decomposition current develops the theory Currents' Physical Components (CPC) for 4-wire circuit with asymmetric voltage. For the first time the unbalanced current is classified by activity and reactivity of asymmetry load elements. Practical value. Practical value of the obtained orthogonal decomposition current and the power equation is a possibility of their utilization for the increase both quality of delivery and quality of consumption of electrical energy.

Authors and Affiliations

Iu. A. Sirotin

Keywords

Related Articles

DYNAMICS MODEL OF MOISTURE IN PAPER INSULATION-TRANSFORMER OIL SYSTEM IN NON-STATIONARY THERMAL MODES OF THE POWER TRANSFORMER

Introduction. An important problem in power transformers resource prognosis is the formation of moisture dynamics trends of transformer insulation. Purpose. Increasing the accuracy of power transformer insulation resourc...

STUDY OF THE MAGNETIC FIELD OF THREE PHASE LINES OF SINGLE CORE POWER CABLES WITH TWO-END BONDING OF THEIR SHIELDS

The study tested the process of the magnetic field (MF) mitigation in the HV three-phase power cable lines (CL) made of single core cables in two-ends bonding of their shields. Developed the technique of numerical simula...

MODELING OF DYNAMIC CHARACTERISTICS OF A NONLINEAR OSCILLATORY SYSTEM WITH A MAGNETIC SPRING. PART 1

A passive magnetic vibration isolator (a magnetic spring) with cylindrical magnets is considered. A mathematical model is developed to calculate magnetic spring magnetic field and force. Numerical calculation of the vibr...

AN OBJECT-ORIENTED FIELD MODEL OF ELECTROMECHANICAL TRANSFORMERS OF ENERGY

Results of theoretical investigations are presented, forming of class structure of electromechanics transformers of energy is shown, the generation of the field models on the basis of principles of the object-oriented an...

THE NORMALIZATION METHODS OF THE STATIC GEOMAGNETIC FIELD INSIDE HOUSES

In the paper, we show the necessity of normalization of the static geomagnetic field (GMF) inside high-rise frame-monolithic houses to safe values (90% of the natural rate at least). Massive ferromagnetic construction of...

Download PDF file
  • EP ID EP297981
  • DOI 10.20998/2074-272X.2016.3.10
  • Views 83
  • Downloads 0

How To Cite

Iu. A. Sirotin (2016). ORTHOGONAL COMPONENTS OF THE THREE-PHASE CURRENT AT ASYMMETRICAL ACTIVE-REACTIVE LOAD IN 4-WIRE CIRCUIT. Електротехніка і Електромеханіка, 0(3), 62-66. https://www.europub.co.uk/articles/-A-297981