Perimetry Comparisons for Octopus G Top and Dynamic Programmes versus Humphrey 24-2 SITA Fast and SITA Standard Programmes
Journal Title: Ophthalmology Research: An International Journal - Year 2014, Vol 2, Issue 1
Abstract
Aims: Previous comparisons of Octopus and Humphrey threshold programmes have shown differences, particularly for depth of defects. Recent developments have altered the Octopus background illumination. Thus, we sought to determine the subsequent extent of differences in results from commonly used central static programmes using Octopus and Humphrey perimeters. Study Design: Diagnostic accuracy study. Place and Duration of Study: Department of Ophthalmology, Warrington and Halton Hospitals NHS Foundation Trust, between June 2009 and July 2012. Methodology: We utilised Octopus G-TOP or G-dynamic programmes and Humphrey 24-2 SITA fast or standard programmes. Poor reliability was taken as errors >25%. Comparison was made for global indices (mean sensitivity, mean deviation, pattern standard deviation/loss variance), test duration from each perimeter using unpaired t tests, and Bland Altman plots for correlation of individual differences between perimeters. Clinical agreement for presence/absence of visual field loss was determined by independent assessment of results by two authors (kappa test). Results: Eighty patients (159 eyes) were recruited. 38 eyes were excluded due to poor reliability. 34 patients (55 eyes) underwent fast static visual field assessment: 17 males and 17 females with a mean age of 63 years (SD 14). 38 patients (64 eyes) underwent standard static visual field assessment: 18 males and 20 females with a mean age of 65 years (SD 13). For both full and fast perimetry, both perimeters showed good agreement for inter observer comparison (K=0.5-0.6). SITA standard perimetry showed a higher mean sensitivity value (+2.5dB±1.0) and SITA fast perimetry showed a higher mean sensitivity value (+3.4dB±1.1) than Octopus values. Bland-Altman analysis showed increasing variability with increasing severity of defect indicating a lack of correlation for moderate to severe visual field results. Conclusions: Visual field results were comparable for mild defects. Octopus perimetry continues to show greater defect size where there is more extensive visual field loss relating to the different strategies used by both perimeters.
Authors and Affiliations
Fiona J. Rowe, Manijeh Wishart, Sarah Spencer
Ocular Manifestations in HIV/AIDS- Prevalence in South India
Human immune deficiency virus (HIV) related ocular manifestations may affect 50-75% of HIV infected people worldwide at some point during the course of their illness. Aim: To estimate the prevalence of Ocular manifestati...
To Assess the Effect of Lighting on Identifying the Ishihara Colour Vision Plates in Trichromats
Aims: The main aim of present study is to investigate the effect of luminance on identifying the Ishihara colour vision plates in normal trichromats. Place and Duration of Study: Dr. Rishi Bhardwaj Visual Psychophysics l...
Outcome of Visual Screening of Hospital Workers in University of Uyo Teaching Hospital, Uyo, South–South Nigeria
Background: The World Glaucoma Week (WGW) is a joint global initiative of the World Glaucoma Association (WGA) and the World Glaucoma Patients Association (WGPA) to raise awareness of glaucoma. As part of the celebration...
Role of Optical Coherence Tomography in Macular Disorders
Optical coherence tomography (OCT) is an emerging technology for performing high-resolution cross-sectional imaging. OCT is analogous to ultrasound imaging, except that it uses light instead of sound. OCT can provide cro...
The Relationship of HLA-B27 and HLA-B51 on Non-Behcet Uveitis
Aims: The aim of this study was to investigate the relationship of human leukocyte antigen (HLA)-B27 and HLA-B51 on the clinical characteristics, demographic features, localization, laterality, treatment modalities and v...