Prediction of Delivery in Women with Threatening Preterm Labour using Phosphorylated Insulin-Like Growth Factor Binding Protein-1 and Cervical Length using Transvaginal Ultrasound
Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 9
Abstract
Introduction: Preterm delivery remains a challenge in Obstetrics as it is responsible for significant cause of perinatal morbidity and mortality. At present there is no standard test for prediction of preterm labour for timely referral to a center with NICU facilities. Aim: To evaluate the effectiveness of the cervical phosphorylated insulin like growth factor binding protein-1(phIGFBP-1), cervical length measurement and combination of phIGFBP-1 with cervical length for Predicting Preterm Labour (PTL). Materials and Methods: It was a observational prospective study done from January 2014 to April 2015 in Department of Obstetrics and Gynaecology, NDMC Medical College and Hindu Rao Hospital, Delhi, India. A total of 100 women with singleton pregnancy, between 24 and 36 weeks of gestation with complaint of uterine contractions were randomly selected. These women were subjected to detect phIGFBP-1 in cervical secretions and cervical length measurement by Transvaginal Sonography (TVS). Result of the test, cervical length and time lapse between test and delivery was noted and the results were analysed. The cervical length less than 25 mm was used as a cut off point for predicting pre-term delivery. Data was analysed using SPSS software version 20.0. Results: The Negative Predictive Value (NPV) of phIGFBP-1 and cervical length was similar (95.2% vs 94.05%) respectively for prediction of preterm labour within one week of admission and 93.92% vs 94.80% at 37 weeks of gestational age. Combined test had higher NPV of 96.38% at 34 weeks of gestation and 94% within two days of admission. Positive Predictive Value (PPV) was low for both the test and combining the two-test did not have any advantage as far as PPV was concerned. Receiver Operating Characteristic (ROC) curve showed that the combined test had a superior result in predicting PTL compared to either phIGFBP-1 or cervical length. The combined test had steepest ROC curve at < 34 weeks of gestation (AUC-0.83 with 95% CI). Conclusion: The phIGFBP-1 test and cervical length have an almost equivalent ability to predict preterm delivery independently. The combined use of phIGFBP-1 and TVS for cervical length shows an increase in efficacy in predicting preterm labour.
Authors and Affiliations
Amrita Kumari, Vandana Saini, P. K. Jain, Mamta Gupta
Mechanical and Adhesive Retention for Bilateral Ear Prosthesis
Images in Medicine
Cisplatin Induced Acute Myocardial Infarction and Dyslipidemia
Myocardial infarction commonly occurs due to rupture of atherosclerotic plaque in the coronary arteries and is manifested on coronary angiography. Myocardial infarction with angiographically normal coronary arteries can...
Dermato-Lymphangitis in Filariasis Resembles Infected Chronic Venous Insufficiency: Two Case Reports and Review of Literature
ABSTRACT Chronic lower limb swelling is frequently encountered in clinical practice. Secondary lymphoedema and chronic venous insufficiency are two frequent causes of chronic lower limb swelling. The most common form of...
Women’s Views on Routine Antenatal Ultrasound Scan in a Low Resource Nigerian Setting
ABSTRACT Introduction: Obstetric ultrasound is a popular and attractive management tool in Obstetrics. In recent times, it has gained wide acceptance amongst expectant mothers in many parts of the developing world. Many...
The Importance of Liver-Fatty Acid Binding Protein in Diagnosis of Liver Damage in Patients with Acute Hepatitis
Introduction: Acute hepatitis is acute inflammation of liver elicited by a large number of causes. It sometimes spontaneously recovers, sometimes may progress to chronic hepatitis. LiverFatty Acid Binding Protein (L-FABP...